Zimmermann G G, Quick H H, Hilfiker P R, von Schulthess K, Giovanoli P, Debatin J F
Department Medizinische Radiologie, Universitätsspital Zürich, Schweiz.
Rofo. 1997 Aug;167(2):180-6. doi: 10.1055/s-2007-1015513.
To evaluate intravascular MR imaging in normal New Zealand rabbits and hereditary hyperlipidaemic Watanabe rabbits (WHHL) with histological correlation.
The suprarenal abdominal aortas of two normal and two WHHL rabbits were examined by conventional angiography, high resolution MRT with a surface coil and intravascular MRT in a 1.5 T system. The intravascular reception coil consisted of a copper wire loop built into the balloon of an angioplasty catheter. The findings were correlated with histological examinations.
Excellent spin echo images with a resolution of 78 x 156 microns were obtained in less than 4 minutes. The arteriosclerotic changes in the vessels of the WHHL rabbits could not be recognised angiographically. High resolution MRT with surface coils showed mural thickening but a detailed demonstration of arteriosclerotic lesions was possible only by means of high resolution intravascular imaging. There was good histological correlation.
Arteriosclerotic lesions can be demonstrated in vivo by high resolution intravascular imaging.
评估正常新西兰兔和遗传性高脂血症渡边兔(WHHL)的血管内磁共振成像,并与组织学结果进行对照。
对两只正常兔和两只WHHL兔的肾上腺腹主动脉进行常规血管造影、使用表面线圈的高分辨率磁共振成像(MRT)以及在1.5T系统中进行血管内MRT检查。血管内接收线圈由内置在血管成形术导管球囊内的铜丝环组成。将检查结果与组织学检查结果进行对照。
在不到4分钟的时间内获得了分辨率为78×156微米的优质自旋回波图像。血管造影无法识别WHHL兔血管中的动脉硬化变化。使用表面线圈的高分辨率MRT显示了管壁增厚,但只有通过高分辨率血管内成像才能详细显示动脉硬化病变。组织学对照良好。
高分辨率血管内成像可在体内显示动脉硬化病变。