流量调节型和压力依赖性流量泵诱导溶血的体外研究。

In vitro study of hemolysis induced by flow-regulated and pressure-dependent flow pumps.

作者信息

Gille J P, Stahl R L

出版信息

Med Prog Technol. 1976 Apr 30;3(4):169-73.

PMID:934039
Abstract

In vitro experiments showed that a pressure-dependent flow pump which "obeys Starling's law" (with flexible tube stretched on vertical rotor) was less hemolytic than a classical flow-regulated pump (with pump inset occluded between a rotor and a stator). The degree of hemolysis obtained with fresh human blood was higher with blood from chronic respiratory patients than with blood from normal donors. Also, the hemolysis was less with fresh heparinized blood than with stored ACD blood, and less with normal blood than with diluted blood. Comparing hemodialysis pumps with ECC pumps showed that hemolysis tripled with the pressure-dependent flow types and was 30 times higher with the classical pumps.

摘要

体外实验表明,一台“遵循斯塔林定律”的压力依赖性流量泵(柔性管在垂直转子上伸展)比传统的流量调节泵(泵体嵌于转子和定子之间)溶血更少。用新鲜人血获得的溶血程度,慢性呼吸疾病患者的血液比正常供血者的血液更高。此外,新鲜肝素化血液的溶血程度低于储存的ACD血液,正常血液的溶血程度低于稀释血液。将血液透析泵与体外循环泵进行比较表明,压力依赖性流量类型的溶血程度增至三倍,而传统泵的溶血程度则高出30倍。

相似文献

1
In vitro study of hemolysis induced by flow-regulated and pressure-dependent flow pumps.流量调节型和压力依赖性流量泵诱导溶血的体外研究。
Med Prog Technol. 1976 Apr 30;3(4):169-73.
2
A new method of producing pulsatile flow during cardiopulmonary bypass using a standard roller pump.一种使用标准滚压泵在体外循环期间产生搏动性血流的新方法。
J Thorac Cardiovasc Surg. 1976 Oct;72(4):585-7.
3
Mechanical performance comparison between RotaFlow and CentriMag centrifugal blood pumps in an adult ECLS model.在成人体外膜肺氧合(ECLS)模型中,RotaFlow和CentriMag离心式血泵的机械性能比较。
Perfusion. 2010 Mar;25(2):71-6. doi: 10.1177/0267659110365366. Epub 2010 Mar 8.
4
Non-occlusive condition with the Better-Header roller pump: impacts of flow dynamics and hemolysis.
Ann Thorac Cardiovasc Surg. 2004 Dec;10(6):357-61.
5
The effects of pressure and flow on hemolysis caused by Bio-Medicus centrifugal pumps and roller pumps. Guidelines for choosing a blood pump.
J Thorac Cardiovasc Surg. 1993 Dec;106(6):997-1007.
6
Significant safety advantages gained with an improved pressure-regulated blood pump.改进后的压力调节血泵具有显著的安全优势。
J Extra Corpor Technol. 1996 Jun;28(2):71-8.
7
Comparative hemolysis study of clinically available centrifugal pumps.临床可用离心泵的比较溶血研究。
Artif Organs. 1996 Jun;20(6):560-3.
8
[Hemolysis test of the five kinds of impeller blood pumps in vitro].[五种叶轮式血泵的体外溶血试验]
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2002 Sep;19(3):479-82.
9
Metabolic comparison of a new pulsatile pump and a roller pump for cardiopulmonary bypass.一种用于体外循环的新型搏动泵与滚压泵的代谢比较。
J Thorac Cardiovasc Surg. 1969 Oct;58(4):562-9.
10
The effect on hemolysis of the raceway profile of roller pumps used in cardiopulmonary bypass.滚压泵在体外循环中对血液红细胞破坏影响的流道形状研究。
ASAIO J. 2012 Jan-Feb;58(1):40-5. doi: 10.1097/MAT.0b013e31820a132c.

引用本文的文献

1
Computer-controlled pulsatile pump system for physiological flow simulation.用于生理血流模拟的计算机控制脉动泵系统。
Med Biol Eng Comput. 1987 Sep;25(5):590-5. doi: 10.1007/BF02441756.