改进后的压力调节血泵具有显著的安全优势。

Significant safety advantages gained with an improved pressure-regulated blood pump.

作者信息

Montoya J P, Merz S I, Bartlett R H

机构信息

MC3, Inc., Ann Arbor, Michigan 48103, USA.

出版信息

J Extra Corpor Technol. 1996 Jun;28(2):71-8.

PMID:10160447
Abstract

A prototype of a non-occlusive pressure-regulated blood pump (M-pump) was evaluated in-vitro for safety in a comparative study with the roller and centrifugal pumps. The M-pump consists of collapsible tubing of unique design wrapped under tension around a rotor without a stator. The prototype M-pumps were tested in vitro to evaluate performance with respect to flow/ pressure characteristics, hemolysis, bubble generation (cavitation) and durability. The M-pump and centrifugal pump did not overpressurize at any RPM when the pump outlet was occluded, but the roller pump reached pressures in excess of 1000 mmHg. The M-pump did not generate negative pressures upon occlusion of the inlet, whereas the roller and centrifugal pumps produced near-vacuum pressures. Furthermore, the M-pump was unable to empty a blood reservoir when the height of the pump inlet was placed slightly above the reservoir outlet. The levels of microbubbles in the M-pump were significantly lower than the roller and centrifugal pumps upon sudden restriction of the pump inlet as determined with an ultrasonic bubble detector. The results of our in-vitro evaluation of the M-pump have shown it to have lower hemolysis than the centrifugal pump and lower or comparable hemolysis to roller pumps at flowrates of 0.1, 0.5, 4.0 and 6 L/min. We determined that the M-pump design possesses important safety advantages over roller and centrifugal pumps for cardiopulmonary bypass applications.

摘要

在一项与滚压泵和离心泵的对比研究中,对一种非阻塞性压力调节血泵(M泵)的原型进行了体外安全性评估。M泵由一种设计独特的可折叠管道组成,该管道在张力作用下缠绕在一个无定子的转子周围。对M泵原型进行了体外测试,以评估其在流量/压力特性、溶血、气泡产生(空化)和耐用性方面的性能。当泵出口被阻塞时,M泵和离心泵在任何转速下都不会出现过压情况,但滚压泵的压力超过了1000 mmHg。当入口被阻塞时,M泵不会产生负压,而滚压泵和离心泵会产生接近真空的压力。此外,当泵入口高度略高于储液器出口时,M泵无法排空储血器。用超声波气泡探测器测定,在泵入口突然受限的情况下,M泵中的微气泡水平明显低于滚压泵和离心泵。我们对M泵的体外评估结果表明,在0.1、0.5、4.0和6 L/min的流速下,其溶血程度低于离心泵,与滚压泵相比溶血程度更低或相当。我们确定,对于体外循环应用,M泵的设计相对于滚压泵和离心泵具有重要的安全优势。

相似文献

1
Significant safety advantages gained with an improved pressure-regulated blood pump.改进后的压力调节血泵具有显著的安全优势。
J Extra Corpor Technol. 1996 Jun;28(2):71-8.
2
Centrifugal pump performance during low-flow extracorporeal CO2 removal; safety considerations.
Perfusion. 2015 Jan;30(1):17-23. doi: 10.1177/0267659114540024. Epub 2014 Jun 11.
3
The effects of pressure and flow on hemolysis caused by Bio-Medicus centrifugal pumps and roller pumps. Guidelines for choosing a blood pump.
J Thorac Cardiovasc Surg. 1993 Dec;106(6):997-1007.
4
Affinity pump system: a new peristaltic blood pump for cardiopulmonary bypass.
Perfusion. 2000 Jan;15(1):77-83. doi: 10.1177/026765910001500111.
5
Non-occlusive condition with the Better-Header roller pump: impacts of flow dynamics and hemolysis.
Ann Thorac Cardiovasc Surg. 2004 Dec;10(6):357-61.
6
An under-occluded roller pump is less hemolytic than a centrifugal pump.
J Extra Corpor Technol. 1997 Mar;29(1):15-8.
7
Laboratory experience with a novel, non-occlusive, pressure-regulated peristaltic blood pump.
ASAIO J. 1992 Jul-Sep;38(3):M406-11. doi: 10.1097/00002480-199207000-00065.
8
Hemolysis generation from a novel, linear positive displacement blood pump for cardiopulmonary bypass on a six kilogram piglet: a preliminary report.
Perfusion. 2017 May;32(4):264-268. doi: 10.1177/0267659116679881. Epub 2016 Nov 18.
9
Mechanical performance comparison between RotaFlow and CentriMag centrifugal blood pumps in an adult ECLS model.在成人体外膜肺氧合(ECLS)模型中,RotaFlow和CentriMag离心式血泵的机械性能比较。
Perfusion. 2010 Mar;25(2):71-6. doi: 10.1177/0267659110365366. Epub 2010 Mar 8.
10
Evaluation of HL-20 roller pump and Rotaflow centrifugal pump on perfusion quality and gaseous microemboli delivery.评价 HL-20 滚压泵和 Rotaflow 离心泵的灌注质量和气体微栓输送。
Artif Organs. 2010 Nov;34(11):937-43. doi: 10.1111/j.1525-1594.2010.01079.x. Epub 2010 Oct 14.

引用本文的文献

1
The role of fetal hemoglobin in the artificial placenta: A premature ovine model.胎儿血红蛋白在人工胎盘中的作用:一个早产绵羊模型。
Perfusion. 2025 Mar;40(2):460-465. doi: 10.1177/02676591241240725. Epub 2024 Mar 22.
2
Tidal Flow Perfusion for the Artificial Placenta: A Paradigm Shift.潮汐流灌注人工胎盘:范式转变。
ASAIO J. 2020 Jul;66(7):796-802. doi: 10.1097/MAT.0000000000001077.
3
Successful Porcine Renal Transplantation After 60 Minutes of Donor Warm Ischemia: Extracorporeal Perfusion and Thrombolytics.供体热缺血60分钟后成功进行猪肾移植:体外灌注与溶栓治疗
ASAIO J. 2015 Jul-Aug;61(4):474-9. doi: 10.1097/MAT.0000000000000228.
4
A novel rotary pulsatile flow pump for cardiopulmonary bypass.一种用于体外循环的新型旋转搏动流泵。
ASAIO J. 2014 May-Jun;60(3):322-8. doi: 10.1097/MAT.0000000000000058.
5
In vitro testing of a novel blood pump designed for temporary extracorporeal support.新型体外临时血液泵的体外测试。
ASAIO J. 2012 Mar-Apr;58(2):109-14. doi: 10.1097/MAT.0b013e318245d356.
6
Preliminary in vivo testing of a novel pump for short-term extracorporeal life support.新型短期体外生命支持泵的初步体内试验。
Ann Thorac Surg. 2012 Jan;93(1):141-6. doi: 10.1016/j.athoracsur.2011.09.014. Epub 2011 Nov 23.
7
Post-arterial filter gaseous microemboli activity of five integral cardiotomy reservoirs during venting: an in vitro study.通气期间五个整体式心脏切开储血器的动脉后滤器气态微栓子活性:一项体外研究。
J Extra Corpor Technol. 2009 Mar;41(1):20-7.
8
A novel, low cost, disposable, pediatric pulsatile rotary ventricular pump for cardiac surgery that provides a physiological flow pattern.一种新型、低成本、一次性使用的儿科搏动性旋转心室泵,用于心脏手术,可提供生理性血流模式。
ASAIO J. 2008 Sep-Oct;54(5):523-8. doi: 10.1097/MAT.0b013e3181870a6d.