• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Quality assessment of blood glucose testing in general practitioners' offices improves quality.

作者信息

Stahl M, Brandslund I, Iversen S, Filtenborg J A

机构信息

Department of Clinical Chemistry, Vejle County Central Hospital, Denmark.

出版信息

Clin Chem. 1997 Oct;43(10):1926-31.

PMID:9342014
Abstract

Measurement of blood glucose is a frequent test in Danish physicians' offices. We describe here a new design of external quality assessment wherein fresh, unstabilized whole-blood samples were analyzed by the physicians' office methods and by a hospital laboratory comparison method (glucose dehydrogenase assay, calibrated against NIST 909a). This approach was used in the offices of 171 general practitioners in our county during a 5-year period. The first survey, in 1992, revealed unsatisfactory performance in terms of our criterion that no difference between the physician's office and the hospital laboratory's single result should exceed +/-20% of the laboratory result. After initiation of a program of consultation and assistance, the proficiency testing rounds of 1994 and 1996 showed considerable improvement. Thus, whereas in 1992 12% of the values were outside the acceptance limits, in 1994 and 1996 the respective values were 4% and 3%. We believe the effect was mainly related to improvements in choice of technology, procedures, and handling of specimens. We conclude that the use of bedside instruments should be restricted to diagnosis of only severe hypo- or hyperglycemia and to monitoring glucose >5 mmo/L in already diagnosed diabetics. Our program differs from previous approaches to quality assessment and could also be useful for large hospitals' in-house proficiency testing.

摘要

相似文献

1
Quality assessment of blood glucose testing in general practitioners' offices improves quality.
Clin Chem. 1997 Oct;43(10):1926-31.
2
Performance of the Kodak DT-60 physician's office analyzer as measured by CLIA-88 proposed evaluation criteria. Assessment of demographic and quality assurance factors influencing performance.
Arch Pathol Lab Med. 1992 May;116(5):524-30.
3
Interinstitutional comparison of bedside blood glucose monitoring program characteristics, accuracy performance, and quality control documentation: a College of American Pathologists Q-Probes study of bedside blood glucose monitoring performed in 226 small hospitals.机构间床边血糖监测项目特征、准确性表现及质量控制文件的比较:美国病理学家学会Q-Probes对226家小型医院床边血糖监测的研究
Arch Pathol Lab Med. 1998 Jun;122(6):495-502.
4
Risk factors for improper vaccine storage and handling in private provider offices.私立医疗机构办公室中疫苗储存和处理不当的风险因素。
Pediatrics. 2001 Jun;107(6):E100. doi: 10.1542/peds.107.6.e100.
5
Quality performance in the physician's office.医生办公室的质量表现。
Med Clin North Am. 1987 Jul;71(4):677-90. doi: 10.1016/s0025-7125(16)30835-5.
6
Longitudinal study of error prevalence in Pennsylvania physicians' office laboratories.
JAMA. 1988 Jul 8;260(2):230-5.
7
The physicians' office laboratory: 1988 and 1996 survey of Illinois pediatricians. Pediatric Practice Research Group.医生办公室实验室:1988年和1996年伊利诺伊州儿科医生调查。儿科实践研究小组。
Arch Pediatr Adolesc Med. 1998 Jun;152(6):585-92. doi: 10.1001/archpedi.152.6.585.
8
Factors related to accuracy in office cholesterol testing. Iowa Academy of Family Physicians Research Network.
J Fam Pract. 1991 Nov;33(5):457-61.
9
Office glucose analysis.
Prim Care. 1986 Dec;13(4):713-25.
10
Are physicians' office laboratory results of comparable quality to those produced in other laboratory settings?医生办公室实验室的检测结果与其他实验室环境下产生的结果质量相当吗?
JAMA. 1998 Feb 11;279(6):468-71. doi: 10.1001/jama.279.6.468.

引用本文的文献

1
Comparability of hemoglobin A1c level measured in capillary versus venous blood sample applying two point-of-care instruments.应用两种即时检测仪器检测毛细血管血样和静脉血样中糖化血红蛋白A1c水平的可比性。
J Diabetes Metab Disord. 2014 Oct 30;13(1):94. doi: 10.1186/s40200-014-0094-1. eCollection 2014.
2
Blood glucose regulation during prolonged, submaximal, continuous exercise: a guide for clinicians.长时间次最大强度持续运动期间的血糖调节:临床医生指南
J Diabetes Sci Technol. 2010 May 1;4(3):694-705. doi: 10.1177/193229681000400325.
3
Systematic review of near patient test evaluations in primary care.
基层医疗中即时检验评估的系统评价
BMJ. 1999 Sep 25;319(7213):824-7. doi: 10.1136/bmj.319.7213.824.