Suppr超能文献

高眼压症和青光眼患者的周边颜色对比度阈值

Peripheral colour contrast thresholds in ocular hypertension and glaucoma.

作者信息

Friström B

机构信息

Department of Ophthalmology, University of Linköping, Sweden.

出版信息

Acta Ophthalmol Scand. 1997 Aug;75(4):376-82. doi: 10.1111/j.1600-0420.1997.tb00393.x.

Abstract

PURPOSE

To evaluate a new test for peripheral colour contrast sensitivity as a tool for early diagnosis of glaucoma.

PATIENTS AND METHODS

Peripheral colour contrast sensitivity was measured by a computer and colour monitor system developed by Arden and co-workers. The monitor displays an annulus subtending 25 degrees at the retina. During the test, 45 degrees of the annulus is removed in one of four quadrants. The patient is asked to identify this quadrant, first at suprathreshold levels and then as the colour contrast between the annulus and the background is varied in order to establish the threshold for identification. The tested colours were varied along the protan, deutan and tritan colour confusion axes, respectively. Thirty-three normal subjects, 22 glaucoma patients and 69 ocular hypertensive patients were examined. The ocular hypertensive patients were divided into a low risk group, a medium risk group and a high risk group.

RESULTS

The colour contrast thresholds for the glaucoma group and the high risk ocular hypertensive group were significantly (p < 0.001) higher for all three colour axes compared with the normal group. There were also significant (p < 0.05-0.001) differences for all axes between the glaucoma group on the one hand and the ocular hypertensive low risk group on the other hand. There were, however, overlaps in colour contrast thresholds between all groups.

CONCLUSION

Although there is a large and statistically significant difference in average colour contrast thresholds between normals and glaucoma patients, it was difficult to find an appropriate cut-off point to separate the two groups. Further studies must clarify the influence of early stages of common diseases such as cataract, diabetes and age-related maculopathy on colour contrast sensitivity.

摘要

目的

评估一种用于周边色觉对比敏感度的新测试,作为青光眼早期诊断的工具。

患者与方法

采用由 Arden 及其同事研发的计算机和彩色显示器系统测量周边色觉对比敏感度。该显示器显示一个在视网膜上张角为25度的环形区域。在测试过程中,环形区域的45度在四个象限之一中被去除。要求患者首先在阈上水平识别该象限,然后随着环形区域与背景之间的颜色对比度变化,以确定识别阈值。分别沿着红色盲、绿色盲和蓝色盲颜色混淆轴改变测试颜色。对33名正常受试者、22名青光眼患者和69名高眼压患者进行了检查。高眼压患者被分为低风险组、中风险组和高风险组。

结果

与正常组相比,青光眼组和高风险高眼压组在所有三个颜色轴上的颜色对比阈值均显著更高(p < 0.001)。青光眼组与高眼压低风险组在所有轴上也存在显著差异(p < 0.05 - 0.001)。然而,所有组之间的颜色对比阈值存在重叠。

结论

尽管正常人与青光眼患者在平均颜色对比阈值上存在很大且具有统计学意义上的差异,但很难找到一个合适的分界点来区分这两组。进一步的研究必须阐明白内障、糖尿病和年龄相关性黄斑病变等常见疾病的早期阶段对颜色对比敏感度的影响。