通过持续输注锝-99m-乙半胱氨酸二聚体对局部脑血流量进行定量分析。

Quantification of regional cerebral blood flow with continuous infusion of technetium-99m-ethyl cysteinate dimer.

作者信息

Tsuchida T, Sadato N, Yonekura Y, Yamamoto K, Waki A, Sugimoto K, Yang J T, Ishizu K, Hayashi N, Ishii Y

机构信息

Department of Radiology and Biomedical Imaging Research Center, Fukui Medical School, Japan.

出版信息

J Nucl Med. 1997 Nov;38(11):1699-702.

PMID:9374336
Abstract

UNLABELLED

We propose a new method to quantify regional cerebral blood flow (rCBF) with continuous infusion of 99mTc-ethyl cysteinate dimer (ECD) and dynamic SPECT.

METHODS

Thirteen subjects were studied. Seven subjects had SPECT and PET studies, and the other six subjects were involved in the measurement of blood clearance of 99mTc-ECD. During constant infusion of 99mTc-ECD (740 MBq) over 10 min, dynamic SPECT scans were obtained every 1 min by means of a triple-head rotating SPECT camera. Intermittent arterial blood sampling with octanol extraction was performed every 1 min to estimate the arterial input function. Influx constant (Ku) obtained by Gjedde-Patlak graphical plot method was compared with rCBF measured by PET using 15O CO2 steady state method. In order to simplify the procedure, arterial input function in each subject was estimated by calibration of the arterial blood sampled at the end of the scan to the standard arterial input function estimated from the blood clearance rate in six subjects.

RESULTS

Ku was linearly correlated with rCBF (Ku = 0.09 + 0.62 rCBF, r = 0.85, p < 0.05). Ku calculated with the estimated input function (Ku') and rCBF also demonstrated a linear relationship (Ku' = 0.05 + 0.65 rCBF, r = 0.84, p < 0.05).

CONCLUSION

The proposed method with one-point arterial sampling is a simple, clinically feasible tool for quantitative measurement of rCBF with 99mTc-ECD.

摘要

未标注

我们提出了一种通过持续输注99mTc - 乙胱氨酸二聚体(ECD)和动态单光子发射计算机断层扫描(SPECT)来定量测定局部脑血流量(rCBF)的新方法。

方法

对13名受试者进行了研究。7名受试者进行了SPECT和正电子发射断层扫描(PET)研究,另外6名受试者参与了99mTc - ECD血液清除率的测量。在10分钟内持续输注99mTc - ECD(740兆贝可)期间,使用三头旋转SPECT相机每隔1分钟进行一次动态SPECT扫描。每隔1分钟进行一次用辛醇萃取的间歇性动脉血采样以估计动脉输入函数。将通过Gjedde - Patlak图形法获得的流入常数(Ku)与使用15O二氧化碳稳态法通过PET测量的rCBF进行比较。为了简化程序,通过将扫描结束时采集的动脉血校准到根据6名受试者的血液清除率估计的标准动脉输入函数来估计每个受试者的动脉输入函数。

结果

Ku与rCBF呈线性相关(Ku = 0.09 + 0.62 rCBF,r = 0.85,p < 0.05)。用估计的输入函数(Ku')计算的Ku与rCBF也显示出线性关系(Ku' = 0.05 + 0.65 rCBF,r = 0.84,p < 0.05)。

结论

所提出的单点动脉采样方法是一种简单、临床可行的工具,可用于用99mTc - ECD定量测量rCBF。