Suppr超能文献

Comparison of left ventricular function and volumes during transesophageal atrial pacing combined with two-dimensional echocardiography in patients with syndrome X, atherosclerotic coronary artery disease, and normal subjects.

作者信息

Anselmi M, Golia G, Marino P, Vitolo A, Rossi A, Caraffi G, Carbonieri E, Zardini P

机构信息

Division of Cardiology, University of Verona, Italy.

出版信息

Am J Cardiol. 1997 Nov 15;80(10):1261-5. doi: 10.1016/s0002-9149(97)00662-0.

Abstract

Nine patients with syndrome X were compared with 2 groups of patients known to have coronary artery disease (CAD) (8 patients who developed regional wall motion abnormalities [group ECHO+] and 6 patients who showed only ST depression at echo-pacing [group ECG+]) and with 6 healthy volunteer control subjects. Left ventricular function at rest was normal in all patients. End-diastolic and end-systolic volumes (ml/m2) and ejection fraction were calculated at baseline and at peak of echo-pacing using a Simpson's biplane method. No regional wall motion abnormalities were observed during the echo-pacing in patients with syndrome X or in the volunteers. End-diastolic volume decreased in patients with syndrome X, in the volunteers (from 47 +/- 11 to 30 +/- 12 and from 72 +/- 7 to 38 +/- 6, respectively, p <0.01 for both), and in ECG+ patients (from 48 +/- 10 to 33 +/- 6, p <0.05), whereas it did not change in ECHO+ patients. End-systolic volume decreased in patients with syndrome X and in the volunteers (from 17 +/- 5 to 11 +/- 4 and from 28 +/- 6 to 16 +/- 4, respectively, p <0.01 for both), whereas it did not change or else slightly increased in patients with CAD (from 18 +/- 10 to 16 +/- 5 for ECG+ patients and from 19 +/- 5 to 24 +/- 9 for ECHO+ patients, p = NS for both), regardless of whether regional wall motion abnormalities appeared. Ejection fraction decreased in ECG+ and ECHO+ patients (from 64 +/- 12 to 52 +/- 11 and from 62 +/- 9 to 44 +/- 13, respectively, p <0.01 for both), whereas it did not change in patients with syndrome X and in the volunteers (from 64 +/- 8 to 61 +/- 8 and from 61 +/- 7 to 58 +/- 7, respectively, p = NS for both). During echo-pacing in syndrome X patients no regional wall motion was detected. Left ventricular volumes and ejection fraction showed the same patterns of variation in these patients as they did in the healthy control subjects, in contrast with those patients with CAD, whether or not regional wall motion abnormalities appeared in the latter.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验