采用双能X线吸收法、生物电阻抗分析法和皮褶人体测量法,对成人脑瘫患者的身体成分进行测定,并与18O同位素稀释技术进行比较。

Body composition in adults with cerebral palsy by dual-energy X-ray absorptiometry, bioelectrical impedance analysis, and skinfold anthropometry compared with the 18O isotope-dilution technique.

作者信息

Hildreth H G, Johnson R K, Goran M I, Contompasis S H

机构信息

Department of Nutritional Sciences, College of Agriculture and Life Sciences, University of Vermont, Burlington 05405, USA.

出版信息

Am J Clin Nutr. 1997 Dec;66(6):1436-42. doi: 10.1093/ajcn/66.6.1436.

Abstract

The aim of this study was to determine in adults with cerebral palsy the accuracy and practicality of standard methods used to estimate body composition. The sample consisted of 20 adults (13 men and 7 women) aged 20-55 y with various degrees of cerebral palsy. Percentage body fat was estimated from skinfold thickness, bioelectrical impedance analysis (BIA), and dual-energy X-ray absorptiometry (DXA), and compared with the reference measure of percentage body fat from total body water by 18O dilution. Values derived from use of BIA and skinfold thickness, estimated by using the Jackson-Pollock equation, were significantly different from those derived with use of 18O dilution (P < 0.001 and P < 0.001, respectively). There was no significant difference between percentage body fat measured with DXA and that measured with 18O. There was favorable agreement between DXA and 18O (mean difference: 0.06 +/- 9.6%), but not between skinfold thickness (mean difference: 6.33 +/- 12.3%) or BIA (mean difference: -6.55 +/- 13.6%) and 18O. Although DXA was the best measure for predicting percentage body fat in the sample, its high cost prohibits its use as a practical method. The best-fitting regression equation specific for this sample by using anthropometric measures to predict percentage body fat was as follows: 8.76 - (7.34 x sex) + (0.32 x weight) + (0.38 x biceps skinfold) (R2 = 0.84, P < 0.001, SEE = 4.85). This equation needs to be cross-validated in an independent sample of adults with cerebral palsy.

摘要

本研究的目的是确定在成年脑瘫患者中,用于估计身体成分的标准方法的准确性和实用性。样本包括20名年龄在20 - 55岁之间、患有不同程度脑瘫的成年人(13名男性和7名女性)。通过皮褶厚度、生物电阻抗分析(BIA)和双能X线吸收法(DXA)估计体脂百分比,并与通过18O稀释法测得的全身水的体脂百分比参考测量值进行比较。使用BIA和皮褶厚度(通过Jackson - Pollock方程估计)得出的值与使用18O稀释法得出的值有显著差异(分别为P < 0.001和P < 0.001)。DXA测量的体脂百分比与18O测量的体脂百分比之间无显著差异。DXA与18O之间有良好的一致性(平均差异:0.06 +/- 9.6%),但皮褶厚度(平均差异:6.33 +/- 12.3%)或BIA(平均差异:-6.55 +/- 13.6%)与18O之间则不然。尽管DXA是预测样本中体脂百分比的最佳方法,但其高成本使其无法作为一种实用方法使用。通过人体测量学方法预测该样本体脂百分比的最佳拟合回归方程如下:8.76 - (7.34×性别) + (0.32×体重) + (0.38×肱二头肌皮褶厚度)(R2 = 0.84,P < 0.001,标准误 = 4.85)。该方程需要在成年脑瘫患者的独立样本中进行交叉验证。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验