Strasburger C J, Dattani M T
Department of Medicine, Innenstadt University Hospital, Ludwig-Maximilians-University, Munich, Germany.
Acta Paediatr Suppl. 1997 Nov;423:5-11. doi: 10.1111/j.1651-2227.1997.tb18361.x.
Three recently published new assays are described for the measurement of growth hormone (GH). Two of these--the eluted stain assay (ESTA) and the immunofunctional assay (IFA)--have been developed to measure the bioactivity of GH, rather than the immunoactivity as measured by conventional radioimmunoassays (RIAs). The third assay--the 22 kDa exclusion assay (22 k GHEA)--is designed to measure the concentrations of the different isoforms of GH present in the circulation. The ESTA is a variant of the Nb2 bioassay for lactogenic hormones, but has been adapted for specific GH measurement in serum samples. It has a lower detection limit than previous bioassays and permits the quantification of GH in large series of samples. The IFA uses a binding-site-specific antibody in combination with GH-binding protein (GHBP) in order to quantify only those GH molecules that are able to dimerize the extracellular domain of the GH receptor (GHBP), which is a prerequisite for GH signal transduction in target cells. The IFA is as convenient to use as immunoassays and can be employed routinely for GH determinations. The clinical usefulness of the 22 k GHEA has not been established, but it should provide a means of augmenting our understanding of the regulation of GH and its various isoforms. Once the ESTA bioassay or the IFA become commercially and widely available, either could replace the RIA as the standard reference method for measuring GH, as both more closely reflect the biologically active proportion of GH in serum samples than that measured by RIA.
本文介绍了最近发表的三种用于测量生长激素(GH)的新检测方法。其中两种——洗脱染色检测法(ESTA)和免疫功能检测法(IFA)——旨在测量GH的生物活性,而非传统放射免疫分析法(RIA)所测量的免疫活性。第三种检测方法——22 kDa排除检测法(22 k GHEA)——则用于测量循环中存在的不同GH异构体的浓度。ESTA是用于催乳激素的Nb2生物检测法的一种变体,但已针对血清样本中的特定GH测量进行了调整。它比以前的生物检测法具有更低的检测限,并允许对大量样本中的GH进行定量。IFA使用结合位点特异性抗体与生长激素结合蛋白(GHBP)相结合,以便仅对那些能够使GH受体(GHBP)的细胞外结构域二聚化的GH分子进行定量,这是GH在靶细胞中信号转导的先决条件。IFA的使用与免疫分析一样方便,可常规用于GH测定。22 k GHEA的临床实用性尚未确立,但它应该能为增进我们对GH及其各种异构体调节的理解提供一种手段。一旦ESTA生物检测法或IFA实现商业化并广泛可用,它们都可以取代RIA作为测量GH的标准参考方法,因为它们比RIA更能准确反映血清样本中具有生物活性的GH比例。