Consecutive serum samples from 26 sarcoidosis patients were examined for circulating immune complex (IC) activity. Fifteen (58%) gave IC-positive reactions in a complement consumption (CC) test and a significant difference as regards anticomplementary was observed when comparing patients in clinical stages 2 and 1 respectively (P less than 0.01) The serum alpha 1-antitrypsin levels were not correlated (r=0.36) to the results of the CC-assay. The duration of IC-occurrence was studied, by two IC-assays, over 1 1/2 to 2 years. The majority of the positive reactions were registered in patients in clinical stage 2. Isolated IC was used for immunization of rabbits. Absorbed immune sera produced a single precipitate of postalbumin mobility with seven out of 36 sarcoidosis sera. In two cases a tailing of the recipitate suggested that the antigen was in complex formation. Immunoelectrophoresis indicated identity between the antigen detected in different sarcoidosis sera. No precipitates were observed using 130 sera from other patients, and screening of 100 blood donors revealed one positive reaction. The antigen, which eluted in the first protein peak on Sephadex G-200, has not been identified serologically.
对26例结节病患者的连续血清样本进行循环免疫复合物(IC)活性检测。15例(58%)在补体消耗(CC)试验中呈IC阳性反应,分别比较临床2期和1期患者时,在抗补体方面观察到显著差异(P<0.01)。血清α1-抗胰蛋白酶水平与CC检测结果无相关性(r=0.36)。通过两种IC检测方法对IC出现的持续时间进行了1年半至2年的研究。大多数阳性反应出现在临床2期患者中。将分离出的IC用于免疫兔子。吸收后的免疫血清与36例结节病血清中的7例产生了单一的后白蛋白迁移率沉淀。在两例中,沉淀出现拖尾现象,提示抗原处于复合物形成状态。免疫电泳显示在不同结节病血清中检测到的抗原具有同一性。使用其他患者的130份血清未观察到沉淀,对100名献血者进行筛查发现1例阳性反应。在Sephadex G-200上第一个蛋白峰中洗脱的抗原,尚未通过血清学方法鉴定。