Suppr超能文献

使用氮13氨标记的正电子发射断层扫描术测量心肌血流和血流储备时的观察者间及研究间变异性。

Interobserver and interstudy variability of myocardial blood flow and flow-reserve measurements with nitrogen 13 ammonia-labeled positron emission tomography.

作者信息

Sawada S, Muzik O, Beanlands R S, Wolfe E, Hutchins G D, Schwaiger M

机构信息

Department of Internal Medicine, University of Michigan Hospitals, Ann Arbor, USA.

出版信息

J Nucl Cardiol. 1995 Sep-Oct;2(5):413-22. doi: 10.1016/s1071-3581(05)80029-7.

Abstract

BACKGROUND

Experimental studies have shown that positron emission tomography (PET) with 13N-labeled ammonia provides accurate quantification of regional myocardial blood flow (MBF) under rest and stress conditions. To establish the clinical utility of this method, the interobserver variability and the temporal variability of serial measurements of blood flow and coronary flow reserve (CFR) must be known. This study investigated the interobserver and temporal reproducibility of 13N-labeled PET for measurement of MBF and CFR.

METHODS AND RESULTS

Initial and follow-up 13N-labeled ammonia PET studies were performed at rest and during adenosine infusion in six normal volunteers and six patients with stable coronary artery disease. Two investigators analyzed dynamically acquired data from the initial studies and one investigator analyzed the follow-up studies. Time-activity curves of tissue tracer activity were derived by a semiautomated sampling routine. A three-compartment model and curve-fitting algorithm were used to determine estimates of MBF in five myocardial regions. The interobserver correlations for MBF and CFR were excellent (r = 0.96 and 0.93, respectively). The interstudy correlation was good for rest and stress MBF (r = 0.87). The estimates of CFR on the initial and follow-up studies demonstrated a fair correlation (r = 0.72). For individual myocardial regions, there was considerable interstudy variability of stress MBF and CFR, with a mean percent difference for CFR of 19% +/- 19% in normal volunteers and 38% +/- 16% in patients with coronary disease. In normal subjects, regional CFR was highly reproducible (95%) when the values were defined as either normal (> or = 2.5) or reduced (< 2.5).

CONCLUSIONS

The interobserver of reproducibility of 13N-labeled ammonia PET estimates of regional MBF was excellent. The temporal reproducibility of MBF and CFR was fair, with individual regions demonstrating substantial interstudy variability.

摘要

背景

实验研究表明,采用13N标记氨的正电子发射断层扫描(PET)可在静息和应激状态下准确量化局部心肌血流量(MBF)。为确定该方法的临床实用性,必须了解观察者间的变异性以及血流和冠状动脉血流储备(CFR)系列测量的时间变异性。本研究调查了13N标记PET测量MBF和CFR的观察者间及时间重复性。

方法与结果

对6名正常志愿者和6名稳定型冠状动脉疾病患者在静息状态及腺苷输注期间进行了初始和随访13N标记氨PET研究。两名研究者分析了初始研究中动态采集的数据,一名研究者分析了随访研究的数据。通过半自动采样程序得出组织示踪剂活性的时间-活性曲线。采用三室模型和曲线拟合算法确定五个心肌区域的MBF估计值。MBF和CFR的观察者间相关性极佳(分别为r = 0.96和0.93)。静息和应激MBF的研究间相关性良好(r = 0.87)。初始和随访研究中CFR的估计值显示出中等相关性(r = 0.72)。对于各个心肌区域,应激MBF和CFR的研究间变异性较大,正常志愿者中CFR的平均百分比差异为19%±19%,冠心病患者中为38%±16%。在正常受试者中,当区域CFR值定义为正常(≥2.5)或降低(<2.5)时,其具有高度可重复性(95%)。

结论

13N标记氨PET估计局部MBF的观察者间重复性极佳。MBF和CFR的时间重复性中等,各个区域在研究间显示出较大变异性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验