Pulse duplicator hydrodynamics of four different bileaflet valves in the mitral position.

作者信息

Verdonck P R, Van Nooten G J, Van Belleghem Y

机构信息

Hydraulics Laboratory, Gent, Belgium.

出版信息

Cardiovasc Surg. 1997 Dec;5(6):593-603. doi: 10.1016/s0967-2109(97)00078-1.

DOI:10.1016/s0967-2109(97)00078-1
PMID:9423945
Abstract

The hydrodynamic performance of four different types of bileaflet heart valve was tested both in steady flow conditions and in a newly designed computerized artificial left heart system. Four 29-mm valves, manufactured by either St. Jude Medical, CarboMedics, ATS Medical or Medtronic Parallel were studied under a steady state and in pulsatile conditions by pressure and flow recording and colour Doppler echocardiography in the 'mitral position' at rest and at exercise (cardiac output range 4-30 l/Min). In the steady state, significant differences were measured at peak flows of 30 l/min, with mean (s.d.) increasing pressure drops (mmHg) recorded at 3.48(0.13) (St. Jude Medical), 3.80(0.11) (Medtronic Parallel), 4.31(0.06) (ATS Medical) (P < 0.005), and 4.78(0.06) (Carbo Medics), (P < 0.005). The mean ratio of the closing volume to the stroke volume was comparable for all valves despite one faulty sample. In the pulsatile state the effective orifice area calculated by the Continuity and Gorlin equations decreased from 2.10(0.04) (ATS Medical), 1.95(0.05) (St. Jude Medical), 1.87(0.03) (Carbo Medics) to 1.67(0.02) (Medtronic Parallel) independently of method used. No significant difference was found in the mean ratio of the regurgitant volume to the stroke volume. The performance index, defined as the ratio of effective orifice area to geometric orifice area ranks the valves in the order ATS Medical (0.44), St. Jude Medical (0.43), Carbo Medics (0.41) and Medtronic Parallel (0.38). Regurgitation visible on colour Doppler echo was a mere consequence of the working principle of the bileaflet valves in the mitral position and was by no means hydrodynamically important nor representative of severe insufficiencies. Differences between the valve types were notable under severe conditions, such as high peak flow.

摘要

相似文献

1
Pulse duplicator hydrodynamics of four different bileaflet valves in the mitral position.
Cardiovasc Surg. 1997 Dec;5(6):593-603. doi: 10.1016/s0967-2109(97)00078-1.
2
In vitro hydrodynamic characteristics among three bileaflet valves in the mitral position.二尖瓣位三种双叶瓣的体外流体动力学特性
Artif Organs. 2000 May;24(5):346-54. doi: 10.1046/j.1525-1594.2000.06498.x.
3
Doppler assessment of prosthetic valve orifice area. An in vitro study.人工瓣膜口面积的多普勒评估:一项体外研究
Circulation. 1992 Jun;85(6):2275-83. doi: 10.1161/01.cir.85.6.2275.
4
Assessment of effective orifice area of prosthetic aortic valves with Doppler echocardiography: an in vivo and in vitro study.用多普勒超声心动图评估人工主动脉瓣的有效瓣口面积:一项体内和体外研究。
J Thorac Cardiovasc Surg. 2001 Aug;122(2):287-95. doi: 10.1067/mtc.2001.115161.
5
Carbomedics and St. Jude Medical bileaflet valves: an in vitro and in vivo comparison.
Eur J Cardiothorac Surg. 1992;6(5):267-71. doi: 10.1016/1010-7940(92)90110-j.
6
Fluid dynamics of the CarboMedics kinetic bileaflet prosthetic heart valve.CarboMedics 双叶型动力人工心脏瓣膜的流体动力学
Eur J Cardiothorac Surg. 1997 Feb;11(2):287-92. doi: 10.1016/s1010-7940(96)01034-2.
7
In vitro investigation of opening behavior and hydrodynamics of bileaflet valves in the mitral position.
Artif Organs. 2002 Jan;26(1):32-9. doi: 10.1046/j.1525-1594.2002.06833.x.
8
An in vitro assessment by means of laser Doppler velocimetry of the medtronic advantage bileaflet mechanical heart valve hinge flow.采用激光多普勒测速法对美敦力卓越双叶机械心脏瓣膜铰链血流进行体外评估。
J Thorac Cardiovasc Surg. 2003 Jul;126(1):90-8. doi: 10.1016/s0022-5223(03)00581-6.
9
In-vitro testing of three totally supra-annular bileaflet mechanical valves: hydrodynamics in the Sheffield pulse duplicator.三种完全超环形双叶机械瓣膜的体外测试:在谢菲尔德脉动模拟器中的流体动力学
J Heart Valve Dis. 2008 Mar;17(2):222-6.
10
In vitro comparison of different mechanical prostheses suitable for replacement of the systemic atrioventricular valve in children.体外比较不同机械假体在儿童系统性房室瓣置换中的应用。
J Thorac Cardiovasc Surg. 2012 Mar;143(3):558-68. doi: 10.1016/j.jtcvs.2011.05.033. Epub 2011 Sep 3.

引用本文的文献

1
Commentary: The importance of understanding fluid dynamics.评论:理解流体动力学的重要性。
JTCVS Open. 2022 Feb 11;9:41-42. doi: 10.1016/j.xjon.2022.02.002. eCollection 2022 Mar.