Suppr超能文献

无晶状体婴儿佩戴硬性透气性角膜接触镜的变化

Rigid gas permeable contact lens changes in the aphakic infant.

作者信息

McQuaid K, Young T L

机构信息

Department of Ophthalmology, University of Minnesota, Minneapolis, USA.

出版信息

CLAO J. 1998 Jan;24(1):36-40.

PMID:9474452
Abstract

PURPOSE

The purpose of this study was to describe and evaluate the frequent parameter changes required in aphakic infants fit with rigid gas permeable (RGP) contact lenses.

METHODS

Twenty-five eyes from 18 patients with congenital cataracts were fit postoperatively with RGP lenses and followed for an average of 19 months. The original lens specifications were determined by keratometer readings, corneal diameter, and axial length or retinoscopy obtained under sedation just prior to or after cataract extraction surgery. The frequency of changes in contact lens power, base curve, and diameter was recorded and analyzed.

RESULTS

Due to rapid growth and/or difficulty in achieving accurate measurements, repeated contact lens adjustments were needed to ensure proper power and fit.

CONCLUSIONS

The data contained in this study indicates a relatively stable period--from 6 to 12 months postoperatively--where the likelihood that contact lenses will need to be modified falls below 50%.

摘要

目的

本研究的目的是描述和评估为无晶状体婴儿验配硬性透气性(RGP)隐形眼镜时所需的常见参数变化。

方法

18例先天性白内障患者的25只眼在术后验配RGP镜片,并平均随访19个月。最初的镜片规格通过角膜曲率计读数、角膜直径以及在白内障摘除手术前或后镇静状态下获得的眼轴长度或检影验光来确定。记录并分析隐形眼镜屈光度、基弧和直径的变化频率。

结果

由于快速生长和/或难以获得准确测量值,需要反复调整隐形眼镜以确保合适的屈光度和配适。

结论

本研究中的数据表明,术后6至12个月为相对稳定期,在此期间需要更换隐形眼镜的可能性低于50%。