Suppr超能文献

[先天性白内障中硬性接触镜矫正无晶状体状态]

[Aphakia correction with rigid contact lenses in congenital cataract].

作者信息

Loudot C, Jourdan F, Benso C, Denis D

机构信息

Le médival, place Général-de-Gaulle, 83160 La Valette, France.

出版信息

J Fr Ophtalmol. 2012 Oct;35(8):599-605. doi: 10.1016/j.jfo.2012.04.003. Epub 2012 May 26.

Abstract

PURPOSE

To describe follow-up and evaluate functional results of rigid gas-permeable contact lens wear for the correction of aphakia in infants after surgery for congenital cataract.

PATIENTS AND METHODS

This retrospective study was performed on 23 eyes of 17 children (12 boys and five girls), between three days and 36 months of age (median 3.5 months), undergoing cataract extraction without primary intraocular lens implantation and fitted only with Menicon(®) Z material contact lenses. Initial fitting visits included history and family education. Subsequent examinations were performed at eight days, 15 days, 1 month, 6 months and 1 year. The four main parameters studied were fit characteristics, ease of manipulation, ocular integrity and lens integrity. Concurrently, functional results (visual acuity, oculomotor balance) and various prognostic factors (associated pathology, age at time of surgery, cataract density, unilaterality versus bilaterality, postoperative complications) were evaluated. Rigorous systematic amblyopia rehabilitation was performed.

RESULTS

At the one-month exam, 60% of parents demonstrated proficiency with manipulating the lens. On one-year follow-up, three cases of failure were attributable to difficulties with lens manipulation. At one year, one infectious complication was detected. The lens material demonstrated good resistance to breakage (9% at one month) and only a mild tendency toward deposits (few or no deposits in 95% of cases at 1 month). With regard to visual outcome, among the children old enough to cooperate, visual acuity was better than 3/10 for nine out of 12 eyes, of which five eyes were 10/10. With regard to alignment, we noted 12 cases (70.6%) of strabismus postoperatively (ten esotropia, two exotropia). The factors predictive of good visual acuity correlated with those described in the literature: partial cataract, bilateral cataract, and absence of postoperative oculomotor disturbance.

CONCLUSION

The characteristics of rigid gas-permeable contact lenses provide safety and efficacy in aphakic infant eyes. They represent an attractive alternative to primary intraocular lens implantation in congenital cataract.

摘要

目的

描述硬性透气性接触镜用于先天性白内障手术后婴儿无晶状体眼矫正的随访情况并评估其功能效果。

患者与方法

本回顾性研究纳入了17名儿童(12名男孩和5名女孩)的23只眼,年龄在3天至36个月之间(中位年龄3.5个月),这些儿童接受了白内障摘除术但未一期植入人工晶状体,仅佩戴了美尼康(®)Z材料的接触镜。初次配镜就诊包括病史询问和家庭教育。后续检查分别在术后8天、15天、1个月、6个月和1年进行。研究的四个主要参数为适配特征、操作便捷性、眼表完整性和镜片完整性。同时,评估功能结果(视力、眼球运动平衡)以及各种预后因素(相关病变、手术时年龄、白内障密度、单眼与双眼、术后并发症)。进行了严格系统的弱视康复治疗。

结果

在1个月的检查中,60%的家长表现出熟练的镜片操作能力。在1年的随访中,3例失败归因于镜片操作困难。1年时,检测到1例感染性并发症。镜片材料显示出良好的抗破损性(1个月时为9%),且仅有轻微的沉积倾向(1个月时95%的病例沉积很少或无沉积)。关于视力结果,在年龄足够大能够配合的儿童中,12只眼中有9只眼的视力优于3/10,其中5只眼为10/10。关于眼位,我们注意到术后有12例(70.6%)斜视(10例内斜视,2例外斜视)。预测良好视力的因素与文献中描述的一致:部分白内障、双侧白内障以及术后无眼球运动障碍。

结论

硬性透气性接触镜的特性为无晶状体婴儿眼提供了安全性和有效性。它们是先天性白内障一期人工晶状体植入的一种有吸引力的替代方法。