Suppr超能文献

骨科手术中使用的布手套比较:临床与实验评估

Comparison of cloth gloves used in orthopaedic surgery: a clinical and experimental evaluation.

作者信息

Herscovici D, DiPasquale T, Sanders R

机构信息

Orthopedic Trauma Service, Tampa General Hospital, Florida, USA.

出版信息

J Orthop Trauma. 1998 Feb;12(2):106-10. doi: 10.1097/00005131-199802000-00007.

Abstract

OBJECTIVES

(a) To compare the effectiveness of five cloth gloves for cut resistance and their ability to prevent inner latex glove perforation. (b) To evaluate the safety, efficacy, and comfort of the outer gloves when reused.

SETTING

Tertiary care level I trauma hospital and biomechanics laboratory.

METHODS

Laboratory evaluation consisting of assessing cut resistance and fabric deterioration and clinical assessment of all cloth gloves worn as a liner between two latex gloves.

RESULTS

Laboratory testing demonstrated significant differences in cut resistance, with gloves divided into three groups: most resistant (Centurion, which required over 3,000 slices or 1,300 chops to failure), resistant (MedArmor, failing at eighty-five slices or 121 chops; Paraderm, failing at thirty-eight slices or ninety-four chops; and Repel, failing at forty-six slices or seventy-five chops), and least resistant (Protek, failing at two slices and less than two chops). Clinically, 3 percent of all the inner latex gloves demonstrated a perforation, with no violation of the skin in any of the five types of cloth gloves used. Only the Protek and MedArmor cloth gloves were positively ranked for comfort.

CONCLUSION

All gloves provided equal protection with respect to inner latex glove perforation during all of the orthopaedic procedures, with comfort being the most important variable. Gloves should be selected based on comfort, because it appears that all gloves provide equal protection during surgery regardless of the material woven into the fabric.

摘要

目的

(a)比较五种布质手套的抗切割效果及其防止内层乳胶手套穿孔的能力。(b)评估外层手套重复使用时的安全性、有效性和舒适度。

地点

一级创伤三级护理医院和生物力学实验室。

方法

实验室评估包括评估抗切割性和织物劣化情况,并对作为两层乳胶手套中间衬里佩戴的所有布质手套进行临床评估。

结果

实验室测试显示抗切割性存在显著差异,手套分为三组:抗切割性最强(百夫长手套,需超过3000次切片或1300次砍击才会破损)、抗切割性较强(MedArmor手套,85次切片或121次砍击时破损;Paraderm手套,38次切片或94次砍击时破损;Repel手套,46次切片或75次砍击时破损)以及抗切割性最弱(Protek手套,2次切片及不到2次砍击时破损)。临床上,所有内层乳胶手套中有3%出现穿孔,而使用的五种布质手套中均未出现皮肤破损情况。只有Protek和MedArmor布质手套在舒适度方面得到正面评价。

结论

在所有骨科手术过程中,所有手套在防止内层乳胶手套穿孔方面提供了同等保护,舒适度是最重要的变量。应根据舒适度选择手套,因为似乎所有手套在手术期间都能提供同等保护,无论织物中编织的材料是什么。