Investigations into the problems associated with electrosurgery machines have concentrated on protecting the patient from radio frequency burns. While protection of the patient is essential an equally serious and dangerous situation exists in protecting the surgeon, particularly the urologist during transurethral resection of the prostate. The 2 subtle causes of burns to the surgeon are reviewed--capacitive coupling and grounding paths that include the surgeon. Protection of the surgeon as well as the patient depends upon an awareness of the peculiar mating of high frequency current and the grounded environment of the operating room.

摘要

对与电外科手术器械相关问题的研究主要集中在保护患者免受射频烧伤。虽然保护患者至关重要,但在保护外科医生方面也存在同样严重且危险的情况,尤其是在经尿道前列腺切除术期间的泌尿科医生。本文回顾了外科医生烧伤的两个细微原因——电容耦合和包括外科医生在内的接地路径。保护外科医生和患者都取决于对高频电流与手术室接地环境特殊匹配关系的认识。