Suppr超能文献

[用棱镜片取代赫歇尔旋转双棱镜和马多克斯双翼镜进行隐斜视检测]

[Replacement of the Herschel revolving double prism and the Maddox double wing with a prismatic glass for testing of heterophoria].

作者信息

Novák I, Svĕrák J

机构信息

Ocní ambulance NsP, Horice v Podkrkonosí.

出版信息

Cesk Slov Oftalmol. 1997 Oct;53(5):321-4.

PMID:9508499
Abstract

After the short summary of investigation methods of latent Squint the authors report about the method using the standard Trial Frame Okula and prism with a power of 16 pdpt, with Maddox lens from common trial case Okula. This method is used for an indication of magnitude of latent Squint for a short and a long distance. After the meaning of the authors is exoforia for a short distance one of the most frequent causes of muscular asthenopic disorders.

摘要

在对潜在斜视的检查方法进行简短总结后,作者报告了使用标准试验框架奥库拉和16棱镜度的棱镜,以及普通试验箱奥库拉中的马多克斯透镜的方法。该方法用于指示短距离和长距离潜在斜视的程度。按照作者的意思,近距离外隐斜是肌肉性眼疲劳障碍最常见的原因之一。