Influences of lung parenchyma density and thoracic fluid on ventilatory EIT measurements.

作者信息

Kunst P W, Vonk Noordegraaf A, Straver B, Aarts R A, Tesselaar C D, Postmus P E, de Vries P M

机构信息

Department of Pulmonary Medicine, Academic Hospital Vrije Universiteit, Amsterdam, The Netherlands.

出版信息

Physiol Meas. 1998 Feb;19(1):27-34. doi: 10.1088/0967-3334/19/1/003.

Abstract

Ventilatory impedance changes can be measured by electrical impedance tomography (EIT). Several studies have pointed out that the ventilatory-induced impedance change measured over the lungs shows a linear relationship with tidal volume. However, EIT measures the ventilatory impedance changes relative to a reference. Therefore, changes in the reference due to lung parenchyma destruction (increase of thoracic impedance) or lung water (decrease of thoracic impedance) might influence ventilatory EIT measurements. A study was designed to evaluate the influence of the density of lung parenchyma and the thoracic fluid content on ventilatory EIT measurements. Eleven emphysema patients with a variable degree of lung parenchyma destruction, nine haemodialysis patients with general fluid overload and ten healthy subjects were measured. The impedance changes were measured with the subject in the supine position breathing a constant tidal volume of 1 litre starting at the maximum end-expiratory level. In the emphysema group a significantly lower impedance change between ins- and expiration was found in comparison with the healthy subjects (11.6 +/- 6.4 AU l-1 versus 18.6 +/- 4.2 AU l-1, p < 0.05), whereas the haemodialysis group showed a significantly larger impedance change between ins- and expiration before haemodialysis (30.5 +/- 13.1 AU l-1, p < 0.05). A significant decrease in ventilation-induced impedance change during dialysis was found (30.5 +/- 13.1 AU l-1 versus 21.4 +/- 8.6 AU l-1, p < 0.01). Furthermore, a significant correlation between lung function parameters, which indicate the severity of lung parenchyma destruction, and the measured impedance change was found in emphysema patients. From these results it can be concluded that the density of lung parenchyma and the thoracic fluid content have a serious impact on the ventilation-induced impedance change.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验