Suppr超能文献

Comparison of biodegradable and metallic tension-band fixation for patella fractures. 38 patients followed for 2 years.

作者信息

Chen A, Hou C, Bao J, Guo S

机构信息

Department of Orthopedics, Changzheng Hospital, Second Military Medical University, Shanghai, China.

出版信息

Acta Orthop Scand. 1998 Feb;69(1):39-42. doi: 10.3109/17453679809002354.

Abstract

We compared the outcome of patella fractures fixed by biodegradable tension-band (B) with self-reinforced polyglycolide or self-reinforced poly-L-lactide plugs and polyester ligaments or by metallic tension-band (M) with Kirschner wires and metallic cerclage wire in a randomized study. 38 fractures (18 with B and 20 with M) were treated. The follow-up time was 24 (14-32) months. The fractures healed in all patients after a medium of 8 weeks. In the B group, the clinical outcome was good in 13, fair in 4, and poor in 1 patient. In the M group, the corresponding figures were 15, 3 and 2. There were no clinical or radiographic differences between the two methods. Patella fractures can be treated, successfully using biodegradable tension-band fixation with no need for a second operation to remove the implants after bone union.