On the use of unshielded cables in ionization chamber dosimetry for total-skin electron therapy.

作者信息

Chen Z, Agostinelli A, Nath R

机构信息

Department of Therapeutic Radiology, Yale-New Haven Hospital, CT, USA.

出版信息

Phys Med Biol. 1998 Mar;43(3):539-46. doi: 10.1088/0031-9155/43/3/006.

DOI:10.1088/0031-9155/43/3/006
PMID:9533133
Abstract

The dosimetry of total-skin electron therapy (TSET) usually requires ionization chamber measurements in a large electron beam (up to 120 cm x 200 cm). Exposing the chamber's electric cable, its connector and part of the extension cable to the large electron beam will introduce unwanted electronic signals that may lead to inaccurate dosimetry results. While the best strategy to minimize the cable-induced electronic signal is to shield the cables and its connector from the primary electrons, as has been recommended by the AAPM Task Group Report 23 on TSET, cables without additional shielding are often used in TSET dosimetry measurements for logistic reasons, for example when an automatic scanning dosimetry is used. This paper systematically investigates the consequences and the acceptability of using an unshielded cable in ionization chamber dosimetry in a large TSET electron beam. In this paper, we separate cable-induced signals into two types. The type-I signal includes all charges induced which do not change sign upon switching the chamber polarity, and type II includes all those that do. The type-I signal is easily cancelled by the polarity averaging method. The type-II cable-induced signal is independent of the depth of the chamber in a phantom and its magnitude relative to the true signal determines the acceptability of a cable for use under unshielded conditions. Three different cables were evaluated in two different TSET beams in this investigation. For dosimetry near the depth of maximum buildup, the cable-induced dosimetry error was found to be less than 0.2% when the two-polarity averaging technique was applied. At greater depths, the relative dosimetry error was found to increase at a rate approximately equal to the inverse of the electron depth dose. Since the application of the two-polarity averaging technique requires a constant-irradiation condition, it was demonstrated than an additional error of up to 4% could be introduced if the unshielded cable's spatial configuration were altered during the two-polarity measurements. This suggests that automatic scanning systems with unshielded cables should not be used in TSET ionization chamber dosimetry. However, the data did show that an unshielded cable may be used in TSET ionization chamber dosimetry if the size of cable-induced error in a given TSET beam is pre-evaluated and the measurement is carefully conducted. When such an evaluation has not been performed, additional shielding should be applied to the cable being used, making measurements at multiple points difficult.

摘要

相似文献

1
On the use of unshielded cables in ionization chamber dosimetry for total-skin electron therapy.
Phys Med Biol. 1998 Mar;43(3):539-46. doi: 10.1088/0031-9155/43/3/006.
2
Total skin electron therapy (TSET): a reimplementation using radiochromic films and IAEA TRS-398 code of practice.全身电子疗法(TSET):使用光致变色胶片和 IAEA TRS-398 实践守则重新实施。
Med Phys. 2010 Jul;37(7):3510-7. doi: 10.1118/1.3442301.
3
Matching the dosimetry characteristics of a dual-field Stanford technique to a customized single-field Stanford technique for total skin electron therapy.将双野斯坦福技术的剂量学特征与定制的单野斯坦福技术用于全身皮肤电子治疗进行匹配。
Int J Radiat Oncol Biol Phys. 2004 Jul 1;59(3):872-85. doi: 10.1016/j.ijrobp.2004.02.046.
4
Electron beam dosimetry of Total Skin Electron Therapy (TSET).全身皮肤电子线治疗(TSET)的电子束剂量测定
Radiol Med. 2004 Nov-Dec;108(5-6):549-59.
5
Spatial distribution of bremsstrahlung in a dual electron beam used in total skin electron treatments: errors due to ionization chamber cable irradiation.全身皮肤电子线治疗中双电子束轫致辐射的空间分布:电离室电缆受照引起的误差
Med Phys. 1994 Nov;21(11):1733-8. doi: 10.1118/1.597215.
6
Cable-induced effects on plane-parallel ionization chamber measurements in large clinical electron beams.电缆对大型临床电子束中平行板电离室测量的影响。
Med Dosim. 1994 Summer;19(2):73-4. doi: 10.1016/0958-3947(94)90074-4.
7
Stopping-power ratios for electron beams used in total skin electron therapy.全身电子束治疗中电子束的阻止本领比。
Med Phys. 2021 Sep;48(9):5472-5478. doi: 10.1002/mp.15121. Epub 2021 Aug 4.
8
Detector response in the buildup region of small MV fields.小兆伏辐射场堆聚区域中的探测器响应。
Med Phys. 2020 Mar;47(3):1327-1339. doi: 10.1002/mp.13973. Epub 2020 Jan 20.
9
Ionization chamber shift correction and surface dose measurements in electron beams.电子束中的电离室移位校正及表面剂量测量
Phys Med Biol. 1998 Nov;43(11):3419-24. doi: 10.1088/0031-9155/43/11/016.
10
Cherenkov imaging method for rapid optimization of clinical treatment geometry in total skin electron beam therapy.用于全身皮肤电子束治疗中临床治疗几何形状快速优化的切伦科夫成像方法。
Med Phys. 2016 Feb;43(2):993-1002. doi: 10.1118/1.4939880.