Manninen V, Reissell P, Paukkala E
Clin Pharmacol Ther. 1976 Sep;20(3):266-8. doi: 10.1002/cpt1976203266.
Ten digitalized patients were monitored for detection of cardiac arrhythmias 0 to 8 hr after daily maintenance dose of digoxin in the fasting state. Transient cardiac arrhythmias attributable to digoxin were seen at 2 to 5 hr in 5 subjects. Initial serum concentrations of digoxin were within standard clinical limits in all subjects, but, higher steady-state levels were present in patients with arrhythmias (1.2 to 1.7 ng/ml) than in the others (0.7 to 1.2 ng/ml). The postadministrative serum peak concentrations were also higher in the patients with arrhythmias.
对10例数字化患者在空腹状态下每日服用维持剂量地高辛后0至8小时进行心律失常监测。5名受试者在2至5小时出现了可归因于地高辛的短暂性心律失常。所有受试者地高辛的初始血清浓度均在标准临床范围内,但出现心律失常的患者稳态水平较高(1.2至1.7纳克/毫升),高于其他患者(0.7至1.2纳克/毫升)。出现心律失常的患者给药后的血清峰值浓度也较高。