Suppr超能文献

可吸收的聚二氧六环酮(PDS-II)缝线与不可吸收的聚丙烯缝线在生长猪主动脉吻合术中的应用

Absorbable PDS-II suture and nonabsorbable polypropylene suture in aortic anastomoses in growing piglets.

作者信息

Chang S H, Weng Z C, Yang A H, Lai S T

机构信息

Department of Surgery, Veterans General Hospital-Taipei, Taiwan.

出版信息

J Formos Med Assoc. 1998 Mar;97(3):165-9.

PMID:9549265
Abstract

The long-term outcome of vascular anastomoses in children can be compromised by stenosis when the growth of the anastomosis does not match that of the vessels. This can be influenced by the suture material. We evaluated the suitability of the new generation of polydioxanone (PDS-II), an absorbable synthetic monofilament suture, in vascular surgery, in terms of permitting normal growth of aortic anastomoses. Ten piglets underwent primary end-to-end anastomosis of the thoracic aorta, five with PDS-II suture and five with conventional polypropylene (Prolene) suture. Six months after surgery, an aortogram was obtained for each animal. The piglets were then killed and the aortas were sent for pathologic examination. Complete absorption of suture material with slight dilatation of the anastomoses was found in all five pigs in the PDS-II suture group. We also found thrombus formation in one pig in this group. Mild stenosis of the anastomotic site was noted in all five pigs in the polypropylene suture group, but no intraluminal thrombus formation was seen. The degree of dilatation or stenosis within each group was not significantly different when intraluminal diameters were compared at three distinct sites in the reconstructed aorta (p > 0.05). The differences in vascular growth between the two groups were also not significant (p > 0.05). Histologic examination revealed less tissue reaction in the PDS-II suture group than in the polypropylene suture group. Thus, PDS-II seems to be a suitable suture material for anastomoses as far as vascular growth is concerned, but the possibility of aneurysm formation secondary to dilatation of the anastomotic site should be kept in mind.

摘要

当吻合口的生长与血管的生长不匹配时,儿童血管吻合的长期结果可能会因狭窄而受到影响。这可能受缝合材料的影响。我们评估了新一代聚二氧六环酮(PDS-II),一种可吸收的合成单丝缝线,在血管手术中对于允许主动脉吻合口正常生长的适用性。十只仔猪接受了胸主动脉端端吻合术,五只使用PDS-II缝线,五只使用传统的聚丙烯(普理灵)缝线。术后六个月,对每只动物进行主动脉造影。然后处死仔猪,将主动脉送去进行病理检查。在PDS-II缝线组的所有五只猪中均发现缝合材料完全吸收,吻合口略有扩张。我们还在该组的一只猪中发现了血栓形成。聚丙烯缝线组的所有五只猪均出现吻合口轻度狭窄,但未见腔内血栓形成。当比较重建主动脉中三个不同部位的管腔直径时,每组内的扩张或狭窄程度无显著差异(p>0.05)。两组之间的血管生长差异也不显著(p>0.05)。组织学检查显示,PDS-II缝线组的组织反应比聚丙烯缝线组少。因此,就血管生长而言,PDS-II似乎是一种适合吻合的缝线材料,但应牢记吻合口扩张继发动脉瘤形成的可能性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验