Suppr超能文献

脊柱融合患者磁共振成像中的金属伪影。植入材料与成像序列的比较。

Metallic artifacts in magnetic resonance imaging of patients with spinal fusion. A comparison of implant materials and imaging sequences.

作者信息

Rudisch A, Kremser C, Peer S, Kathrein A, Judmaier W, Daniaux H

机构信息

Department of Radiology, University Hospital of Innsbruck, Austria.

出版信息

Spine (Phila Pa 1976). 1998 Mar 15;23(6):692-9. doi: 10.1097/00007632-199803150-00009.

Abstract

STUDY DESIGN

Devices for spinal fusion were compared with respect to their influence on magnetic resonance images. In addition, different magnetic resonance pulse sequences were evaluated to elicit their susceptibility to imaging artifacts.

OBJECTIVES

To determine the implants with the least imaging artifacts as a recommendation for the spine surgeon and to assess the best imaging strategy for the radiologist.

SUMMARY OF BACKGROUND DATA

For patients who have had surgical spinal fusion with instrumentation, magnetic resonance imaging is the most favorable diagnostic method. Unfortunately, metallic implants lead to severe degradation of image quality. These artifacts depend on the material of the implant and on the choice of the pulse sequence.

METHODS

The fusion devices were mounted on a simple plastic phantom in various combinations and were imaged on 1.5-T magnetic resonance units. Frequently used types of plates and screws made of titanium or steel in various alloys were examined on the phantom with routinely used pulse sequences. The results of these examinations were compared with those in patient studies involving the same implants as well as the same pulse sequences.

RESULTS

The least imaging artifacts were caused by titanium implants, especially when using shorter screws, wider screw placement, and thinner titanium plates. Nevertheless, there were distinct image distortions that could lead to erroneous image interpretation. The best images were acquired by spin echo (T1), turbo spin echo (T1, T2), and half Fourier single shot turbo spin echo (HASTE) sequences. Sequences containing any gradient echo components (gradient echo or turbo gradient and spin echo sequence or frequency-selective fat saturation techniques) resulted in the highest amount of image degradation.

CONCLUSION

By choosing appropriate spinal fusion devices as well as pulse sequences, postoperative magnetic resonance imaging examinations can give acceptable results, in spite of the presence of metallic implants.

摘要

研究设计

对用于脊柱融合的器械在其对磁共振图像的影响方面进行比较。此外,对不同的磁共振脉冲序列进行评估,以确定它们对成像伪影的敏感性。

目的

确定产生成像伪影最少的植入物,为脊柱外科医生提供建议,并为放射科医生评估最佳成像策略。

背景资料总结

对于接受了器械辅助脊柱融合手术的患者,磁共振成像(MRI)是最有利的诊断方法。不幸的是,金属植入物会导致图像质量严重下降。这些伪影取决于植入物的材料以及脉冲序列的选择。

方法

将融合器械以各种组合安装在一个简单的塑料模型上,并在1.5-T磁共振设备上成像。在模型上检查了由各种合金制成的常用类型的钛或钢质钢板和螺钉,并使用常规脉冲序列。将这些检查结果与涉及相同植入物和相同脉冲序列的患者研究结果进行比较。

结果

钛植入物产生的成像伪影最少,特别是使用较短螺钉、较宽螺钉间距和较薄钛板时。然而,仍存在明显的图像失真,可能导致错误的图像解读。通过自旋回波(T1)、快速自旋回波(T1、T2)和半傅里叶单次激发快速自旋回波(HASTE)序列可获得最佳图像。包含任何梯度回波成分的序列(梯度回波或快速梯度和自旋回波序列或频率选择性脂肪饱和技术)导致的图像退化程度最高。

结论

通过选择合适的脊柱融合器械和脉冲序列,尽管存在金属植入物,术后磁共振成像检查仍可获得可接受的结果。

文献AI研究员