• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Microhardness and anisotropy of the vital osseous interface and endosseous implant supporting bone.

作者信息

Huja S S, Katona T R, Moore B K, Roberts W E

机构信息

Biomechanics and Biomaterial Research Center, Indiana University-Purdue University at Indianapolis, and Indiana University School of Dentistry, 46202, USA.

出版信息

J Orthop Res. 1998 Jan;16(1):54-60. doi: 10.1002/jor.1100160110.

DOI:10.1002/jor.1100160110
PMID:9565074
Abstract

Limited information is available on the mechanical properties of the rapidly remodeling bone that surrounds endosseous implants. Fifteen implant-bone blocks were obtained from the mid-femoral diaphyses of three mature male hounds 12 weeks after placement of the implants. To evaluate the microhardness and cortical anisotropy of bone, the implants were sectioned along their long axes. In this process, the femurs were sectioned transversely. Knoop microhardness measurements (HK) were made with a 50 g force on cortical bone and a 25 g force on periosteal callus, endocortical callus, and circumferential lamellar bone. The long diagonal of the indenter was placed parallel to the implant (in the radial bone direction). Measurements were made in cortical bone at 200, 400, 600, 800, 1,000, 1,500, 2,000, and 2,500 microm from both sides of the implant. To detect cortical anisotropy in the radial compared with the tangential direction, a second set of indentations was made perpendicular to the first. Microhardness of periosteal callus and endocortical callus and anisotropy of circumferential lamellar bone near the endocortical surfaces of the femur were also evaluated. Repeated measures analysis of variance showed significantly (p < 0.05) lower microhardness values (30.6 +/- 0.8 HK [mean +/- SEM]) for cortical bone at 200 microm than at any other location (range: 40.3-46.6 HK). Microhardness anisotropy was not detected in cortical bone. Furthermore, within 200 microm of the implant surface, the Knoop microhardness values were significantly lower for periosteal and endocortical calluses than for cortical bone. These data provide information about the mechanical properties of bone adjacent to endosseous implants at a microstructural level. The results are consistent with the high rate of remodeling seen adjacent to endosseous implants at 12 weeks after implantation.

摘要

相似文献

1
Microhardness and anisotropy of the vital osseous interface and endosseous implant supporting bone.
J Orthop Res. 1998 Jan;16(1):54-60. doi: 10.1002/jor.1100160110.
2
Surface analysis and effects on interfacial bone microhardness of collagen-coated titanium implants: a rabbit model.胶原涂层钛植入物的表面分析及其对界面骨微硬度的影响:兔模型
Int J Oral Maxillofac Implants. 2005 Jan-Feb;20(1):23-30.
3
Remodeling of devitalized bone threatens periosteal margin integrity of endosseous titanium implants with threaded or smooth surfaces: indications for provisional loading and axially directed occlusion.
J Indiana Dent Assoc. 1989 Jul-Aug;68(4):19-24.
4
Bone tissue interface.
J Dent Educ. 1988 Dec;52(12):804-9.
5
Effects of callus and bonding on strains in bone surrounding an implant under bending.
Int J Oral Maxillofac Implants. 1998 Sep-Oct;13(5):630-8.
6
Histomorphometric, ultrastructural and microhardness evaluation of the osseointegration of a nanostructured titanium oxide coating by metal-organic chemical vapour deposition: an in vivo study.通过金属有机化学气相沉积法对纳米结构氧化钛涂层骨整合的组织形态计量学、超微结构和显微硬度评估:一项体内研究。
Biomaterials. 2004 Nov;25(25):5583-91. doi: 10.1016/j.biomaterials.2004.01.017.
7
A study of the bone healing kinetics of plateau versus screw root design titanium dental implants.一项关于平台型与牙根型钛牙种植体骨愈合动力学的研究。
Clin Oral Implants Res. 2009 Mar;20(3):232-9. doi: 10.1111/j.1600-0501.2008.01640.x.
8
Histomorphometric and fluorescence microscopic evaluation of interfacial bone healing around 3 different dental implants before and after radiation therapy.放射治疗前后3种不同牙科种植体周围界面骨愈合的组织形态计量学和荧光显微镜评估。
Int J Oral Maxillofac Implants. 2006 Mar-Apr;21(2):212-24.
9
Implant-bone interface stress distribution in immediately loaded implants of different diameters: a three-dimensional finite element analysis.不同直径即刻负重种植体的种植体-骨界面应力分布:三维有限元分析
J Prosthodont. 2009 Jul;18(5):393-402. doi: 10.1111/j.1532-849X.2009.00453.x. Epub 2009 Apr 3.
10
Resonance frequency measurements in vivo and related surface properties of magnesium-incorporated, micropatterned and magnesium-incorporated TiUnite, Osseotite, SLA and TiOblast implants.体内共振频率测量以及含镁、微图案化的含镁TiUnite、Osseotite、SLA和TiOblast种植体的相关表面特性
Clin Oral Implants Res. 2009 Oct;20(10):1146-55. doi: 10.1111/j.1600-0501.2009.01767.x. Epub 2009 Aug 30.

引用本文的文献

1
Bone regeneration potential of a soybean-based filler: experimental study in a rabbit cancellous bone defects.基于大豆的填充物的骨再生潜力:兔松质骨缺损的实验研究。
J Mater Sci Mater Med. 2010 Feb;21(2):615-26. doi: 10.1007/s10856-009-3870-6. Epub 2009 Sep 22.