Di Salvo D N, Benson C B, Laing F C, Brown D L, Frates M C, Doubilet P M
Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA.
AJR Am J Roentgenol. 1998 May;170(5):1295-8. doi: 10.2214/ajr.170.5.9574605.
Velamentous and marginal umbilical cords are uncommon abnormalities of placental cord insertion that can entail significant fetal risk. We undertook this investigation to assess the ability of prenatal sonography to reveal abnormal insertions of the umbilical cord into the placenta.
Forty-six patients had both prenatal sonographic evaluation of the placental cord insertion site and postnatal pathologic examination. Distance from the insertion site to the nearest placental edge was categorized by sonography and pathology as normal if greater than 1 cm and abnormal if less than or equal to 1 cm. Sonographic and pathologic findings were compared.
Thirty-eight singleton and eight twin pregnancies, for a total of 54 cord insertions, were studied. Of the 43 sonographically normal insertions, 38 had normal pathologic findings, and the remaining five insertions had abnormal pathologic findings (all marginal cord insertions). All 11 insertions that showed abnormality on sonography were abnormal on pathologic examination (seven marginal and four velamentous insertions). Sonography was able to reveal a difference between the two types of abnormal insertions in only a single patient, in whom the cord insertion changed from marginal to velamentous during a 7-week interval. Sonography had an overall sensitivity of 69% (11/16), a specificity of 100% (38/38), and an accuracy of 91% (49/54) for revealing abnormal placental cord insertion sites.
Targeted sonographic examination of the placental site of umbilical cord insertion will reveal abnormal placental cord insertions, although distinguishing the specific type of abnormal insertion may require the use of color Doppler imaging.
帆状脐带和边缘性脐带附着是胎盘脐带插入的罕见异常情况,可能给胎儿带来重大风险。我们开展此项研究以评估产前超声检查揭示脐带插入胎盘异常的能力。
46例患者均接受了产前胎盘脐带插入部位的超声评估及产后病理检查。超声和病理检查将脐带插入部位到最近胎盘边缘的距离分类为:大于1cm为正常,小于或等于1cm为异常。比较超声和病理检查结果。
研究了38例单胎妊娠和8例双胎妊娠,共54处脐带插入情况。在43例超声检查正常的插入情况中,38例病理检查结果正常,其余5例插入情况病理检查结果异常(均为边缘性脐带附着)。所有11例超声检查显示异常的插入情况病理检查均为异常(7例边缘性和4例帆状附着)。超声仅在1例患者中能够区分两种类型的异常插入情况,该患者在7周内脐带插入从边缘性变为帆状。超声检查揭示胎盘脐带插入异常部位的总体敏感度为69%(11/16),特异度为100%(38/38),准确度为91%(49/54)。
针对胎盘脐带插入部位的超声检查可揭示胎盘脐带插入异常,尽管区分异常插入的确切类型可能需要使用彩色多普勒成像。