Suppr超能文献

Correct utilization of exercise electrocardiographic leads in differentiation of men with coronary artery disease from patients with a low likelihood of coronary artery disease using peak exercise ST-segment depression.

作者信息

Viik J, Lehtinen R, Turjanmaa V, Niemelä K, Malmivuo J

机构信息

Ragnar Granit Institute, Tampere University of Technology, Finland.

出版信息

Am J Cardiol. 1998 Apr 15;81(8):964-9. doi: 10.1016/s0002-9149(98)00073-3.

Abstract

In this study we compared the diagnostic characteristics of the individual exercise electrocardiographic leads, 3 different lead sets comprising standard leads and the effect of the partition value in the detection of coronary artery disease (CAD). The diagnostic variable used was ST-segment depression at peak exercise, and the study population consisted of 101 patients with CAD and 100 patients with a low likelihood of the disease. The lead system used was the Mason-Likar modification of the standard 12-lead system and exercise tests were performed on a bicycle ergometer. The comparisons were performed by means of receiver-operating characteristic analysis and by determining sensitivities at a fixed 95% specificity. These properties, defined here as diagnostic capacity, were the most efficacious in leads I, -aVR, V4, V5, and V6. Diagnostic capacities in leads aVL, aVF, III, V1, and V2 were quite poor; statistical comparisons indicated significant differences between these leads and lead V5 (p < or = 0.0001 in each case). Use of the maximum value of ST-segment depression at peak exercise derived from all 12 leads produced a considerable decrease in the diagnostic capacity of the exercise electrocardiogram compared with lead V5. The exclusion of leads aVL, V1, and III improved the diagnostic capacity compared with the 12-lead set, but it was still smaller than that of lead V5. With use of a lead set with the 5 best leads increased the diagnostic capacity over other lead sets and over any individual lead. Further improvement was noted when a 50% smaller partition value was applied to leads I and -aVR than for the other leads (p = 0.041). In conclusion, this study suggests that use of leads I, -aVR, V4, V5, and V6 is the most influential when differentiating between patients with CAD and patients with a low likelihood of disease using peak exercise ST-segment depression. The effective use of leads I and -aVR requires the partition value applied for these leads to be 50% smaller than that used for the lateral precordial leads.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验