Suppr超能文献

可回收支架型人工血管腔内修复胸主动脉瘤时脊髓缺血预测的初步报告

Preliminary report on prediction of spinal cord ischemia in endovascular stent graft repair of thoracic aortic aneurysm by retrievable stent graft.

作者信息

Ishimaru S, Kawaguchi S, Koizumi N, Obitsu Y, Ishikawa M

机构信息

Second Department of Surgery, Tokyo Medical College, Japan.

出版信息

J Thorac Cardiovasc Surg. 1998 Apr;115(4):811-8. doi: 10.1016/S0022-5223(98)70360-5.

Abstract

OBJECTIVE

To predict spinal cord ischemia after endovascular stent graft repair of descending thoracic aortic aneurysms, temporary interruption of the intercostal arteries (including the aneurysm) was performed by placement of a novel retrievable stent graft (Retriever) in the aorta under evoked spinal cord potential monitoring.

METHODS

From February 1995 to October 1997, endovascular stent graft repair of descending thoracic aortic aneurysms was performed in 49 patients after informed consent was obtained. In 16 patients with aneurysms located in the middle and distal segment of the descending aorta, the Retriever was placed temporarily before stent graft deployment. The Retriever consisted of two units of self-expanding zigzag stents connected in tandem with stainless steel struts. Each strut was collected in a bundle fixed to a pushing rod, and the stent framework was lined with an expanded polytetrafluoroethylene sheet. The Retriever was delivered beyond the aneurysm through a sheath and was retracted into the sheath 20 minutes later. A stent graft for permanent use was deployed in patients whose predeployment test results with the Retriever were favorable. Evoked spinal cord potential was monitored throughout placement of the Retriever and stent grafting until the next day.

RESULTS

The Retriever was placed in 17 aneurysms in 16 patients. There were no changes in amplitude or latency of evoked spinal cord potential records obtained before or during Retriever placement. After withdrawal of the Retriever, all aneurysms were excluded from circulation immediately after permanent stent grafting. There were no changes in evoked spinal cord potential, nor were neurologic deficits seen after stent graft deployment in any patient.

CONCLUSIONS

These results suggest that predeployment testing with the Retriever under evoked spinal cord potential monitoring is promising as a predictor of spinal cord ischemia in candidates for stent graft repair of thoracic aortic aneurysms.

摘要

目的

为预测降主动脉瘤腔内支架修复术后脊髓缺血情况,在脊髓诱发电位监测下,通过在主动脉内放置一种新型可回收支架移植物(Retriever),对肋间动脉(包括动脉瘤)进行临时阻断。

方法

1995年2月至1997年10月,在获得49例患者知情同意后,对降主动脉瘤进行腔内支架修复。在16例动脉瘤位于降主动脉中、远端节段的患者中,在植入支架移植物前临时放置Retriever。Retriever由两个串联的自膨式锯齿状支架单元组成,通过不锈钢支柱连接。每个支柱收集成一束,固定在推杆上,支架框架内衬有膨体聚四氟乙烯片。Retriever通过鞘管输送至动脉瘤上方,20分钟后收回鞘管。对Retriever预植入测试结果良好的患者植入永久性支架移植物。在整个Retriever放置和支架植入过程中以及直至次日,均监测脊髓诱发电位。

结果

16例患者的17个动脉瘤中放置了Retriever。在放置Retriever之前或期间,脊髓诱发电位记录的波幅或潜伏期均无变化。收回Retriever后,所有动脉瘤在永久性支架植入后立即被排除在循环之外。脊髓诱发电位无变化,且在任何患者支架植入后均未出现神经功能缺损。

结论

这些结果表明,在脊髓诱发电位监测下使用Retriever进行预植入测试,有望成为胸主动脉瘤支架修复候选患者脊髓缺血的预测指标。