The blood-gas partition coefficient of xenon may be lower than generally accepted.

作者信息

Goto T, Suwa K, Uezono S, Ichinose F, Uchiyama M, Morita S

机构信息

Department of Anaesthesia, Teikyo University School of Medicine, Ichihara Hospital, Chiba, Japan.

出版信息

Br J Anaesth. 1998 Feb;80(2):255-6. doi: 10.1093/bja/80.2.255.

Abstract

The blood-gas partition coefficients of xenon, reported more than 25 yr ago in the literature, vary considerably from 0.13 to 0.20. Consequently, we have determined this variable by directly injecting xenon-saturated blood into a gas chromatograph-mass spectrometer. This technique yielded a blood-gas partition coefficient for xenon of 0.115 (95% confidence interval 0.107-0.123). The solubility in water measured identically was 0.096, consistent with the reported value of 0.085. These data and a detailed review of the literature strongly suggest that the blood-gas partition coefficient of xenon may be lower than the generally accepted value of 0.14.

摘要

25年多前文献报道的氙气血气分配系数在0.13至0.20之间有很大差异。因此,我们通过将氙气饱和血液直接注入气相色谱 - 质谱仪来测定这个变量。该技术得出氙气的血气分配系数为0.115(95%置信区间0.107 - 0.123)。同样方法测得的在水中的溶解度为0.096,与报道值0.085一致。这些数据以及对文献的详细综述有力地表明,氙气的血气分配系数可能低于普遍接受的0.14的值。