PURPOSE

This study was conducted to determine the agreement and test-retest repeatability of two methods for measuring corneal curvature in keratoconus: keratometry and the First Definite Apical Clearance Lens (FDACL). Our interest in the FDACL procedure stems from the important contact lens-fitting information and documentation of disease progression provided by the FDACL trial lenses and observation of fluorescein patterns.

METHODS

The Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study is an observational study that has enrolled 1,209 keratoconus patients to characterize the progression of keratoconus, to determine factors associated with its progression, and to assess its impact on quality of life. Ten percent of the patients were randomly selected at baseline for a retest examination. The baseline examination, which included keratometry and FDACL, was repeated in this sample. The FDACL is the flattest lens in the standardized CLEK trial lens set that vaults the apex of the cone. FDACL provides an estimate of the sagittal height of the cone.

RESULTS

The correlation of FDACL with the steep keratometric reading (r = 0.89; p = 0.0001) and the flat keratometric reading (r = 0.83; p = 0.0001) were high. Test-retest repeatability as measured by the intraclass correlation coefficient (ICC) was high: FDACL ICC, 0.97; steep keratometric reading ICC, 0.96; and flat keratometric reading ICC, 0.95. Test-retest repeatability of FDACL remained high in advanced disease.

CONCLUSION

FDACL provides a repeatable new procedure for determining disease severity in keratoconus.

摘要

目的

本研究旨在确定圆锥角膜两种角膜曲率测量方法的一致性和重测重复性:角膜曲率计测量法和首次明确顶端间隙镜片(FDACL)测量法。我们对FDACL测量法感兴趣的原因在于,FDACL试验镜片能提供重要的隐形眼镜验配信息及疾病进展记录,并且可以观察荧光素图案。

方法

圆锥角膜协作纵向评估(CLEK)研究是一项观察性研究,已招募1209例圆锥角膜患者,以描述圆锥角膜的进展情况,确定与其进展相关的因素,并评估其对生活质量的影响。在基线时随机选择10%的患者进行复测检查。对该样本重复进行包括角膜曲率计测量法和FDACL测量法的基线检查。FDACL是标准化CLEK试验镜片组中使圆锥顶端呈圆顶状的最平镜片。FDACL可估算圆锥的矢高。

结果

FDACL与角膜曲率计测量的陡峭读数(r = 0.89;p = 0.0001)和平坦读数(r = 0.83;p = 0.0001)的相关性很高。用组内相关系数(ICC)衡量的重测重复性很高:FDACL的ICC为0.97;角膜曲率计测量的陡峭读数的ICC为0.96;角膜曲率计测量的平坦读数的ICC为0.95。在晚期疾病中,FDACL的重测重复性仍然很高。

结论

FDACL为确定圆锥角膜疾病严重程度提供了一种可重复的新方法。