Di Martino E, Mantero S, Inzoli F, Melissano G, Astore D, Chiesa R, Fumero R
Dipartimento di Bioingegneria, Politecnico di Milano, Italy.
Eur J Vasc Endovasc Surg. 1998 Apr;15(4):290-9. doi: 10.1016/s1078-5884(98)80031-2.
To evaluate the role played by biomechanical and geometrical parameters of endoluminal thrombus and of aortic wall on abdominal aortic aneurysm (AAA) behaviour.
Tensile tests on 21 AAA thrombus specimens from six patients undergoing AAA repair and numerical evaluation of aneurysmal aortic wall stress and strain distribution. Parameters of the analysis were lumen eccentricity, thrombus Young's Modulus and the aortic wall constitutive equation.
There was a linear stress/strain for all the thrombus specimens. The numerical analyses show the mechanical behaviour of AAA as a function of lumen eccentricity and biomechanical parameters.
Well organised thrombus reduces the effect of the pressure load on the aneurysmal aortic wall.
评估腔内血栓和主动脉壁的生物力学及几何参数对腹主动脉瘤(AAA)行为的作用。
对6例接受AAA修复手术患者的21个AAA血栓样本进行拉伸试验,并对动脉瘤主动脉壁的应力和应变分布进行数值评估。分析参数包括管腔偏心度、血栓杨氏模量和主动脉壁本构方程。
所有血栓样本均呈现线性应力/应变关系。数值分析表明AAA的力学行为是管腔偏心度和生物力学参数的函数。
结构良好的血栓可降低压力负荷对动脉瘤主动脉壁的影响。