Suppr超能文献

多通道人工耳蜗对前庭功能的影响。

Influence of the multichannel cochlear implant on vestibular function.

作者信息

Ito J

机构信息

Department of Otolaryngology, Otsu Red Cross Hospital, Nagara, Japan.

出版信息

Otolaryngol Head Neck Surg. 1998 Jun;118(6):900-2. doi: 10.1016/S0194-5998(98)70295-5.

Abstract

Vestibular function was examined in 55 adult patients who underwent cochlear implant surgery. The percentages of the patients with normal results on an optokinetic nystagmus test and eye-tracking test before surgery were 85% and 82%, respectively. A caloric stimulation test was performed before surgery, and 67% of patients showed hypofunction or afunction. This same test was performed approximately 1 month after surgery, and 38% of patients showed functional deterioration. After surgery 47% of the patients reported some kind of subjective dizziness. The characteristics of dizziness were divided into three types: early, prolonged, and delayed. Fifty-eight percent of the patients had early type, 34% had prolonged type, and 8% had the delayed type. Eighteen percent of the patients felt dizziness when they used the implant device, indicating that electrical current spread from the implant device to the vestibular nerve. The other 82% of the patients did not report any relationship between the use of their cochlear implants and dizziness.

摘要

对55例接受人工耳蜗植入手术的成年患者进行了前庭功能检查。术前视动性眼震试验和眼动追踪试验结果正常的患者比例分别为85%和82%。术前进行了冷热刺激试验,67%的患者表现为功能减退或功能丧失。术后约1个月进行了同样的试验,38%的患者出现功能恶化。术后47%的患者报告有某种主观头晕。头晕的特征分为三种类型:早期、持续和延迟。58%的患者为早期类型,34%为持续类型,8%为延迟类型。18%的患者在使用植入装置时感到头晕,表明电流从前庭神经扩散到植入装置。其他82%的患者未报告使用人工耳蜗与头晕之间存在任何关联。