A three year experience with the toronto stentless porcine valve.

作者信息

Berg G A, McLaughlin K E, Akar R, Pathi V, MacArthur K J

机构信息

Department of Cardiothoracic Surgery, Western Infirmary, Dumbarton Road, Glasgow G11 6NT, Scotland.

出版信息

Ann Thorac Cardiovasc Surg. 1998 Jun;4(3):138-45.

PMID:9660911
Abstract

In the three year period from March 1994, 112 Toronto Stentless Porcine Valves (SPV TM) were implanted in the Western Infirmary, Glasgow. There were 55 males and 57 females aged between 45 and 86 years (mean 70.9 +/- 7.2 yrs). The mean preoperative aortic gradient was 89 +/- 27 mmHg. Fifty-three patients (47%) had an isolated first time aortic valve replacement. Myocardial revascularisation was carried out in 51 patients (46%) with a mean of 1.7 +/- 0.9 coronary bypass grafts per patient. Six patients (5.3%) had associated mitral valve procedures and six patients (5.3%) had previous open heart surgery. Four patients (3.6%) had a minimally invasive procedure. There was one perioperative death (0.9%) which was not valve related. Of the 111 survivors there were three late deaths (cerebrovascular accident at two months and congestive cardiac failure at two months and four months). Two patients developed prosthetic valve endocarditis at three and five months respectively, one requiring a repair of a periprosthetic leak. To compare the effects of stented and stentless prostheses on early haemodynamic function and late left ventricular mass regression, a prospective randomized clinical trial was conducted. Following valve sizing, 20 patients were randomized to receive a Carpentier-Edwards SAV stented bioprosthesis (mean annular size-25.3 mm, mean valve size-23 mm) of which eight also had bypass grafts. Twenty patients were randomized to receive a Toronto SPV (mean annular size-25.5 mm, mean valve size-26 mm) of which nine had bypass grafts. The stentless valve group had a longer ischaemic time (77.9 +/- 20.9 min v 60.9 +/- 21.9 min) and bypass time (101.7 +/- 27.1 min v 82.9 +/- 20.2 min). Using continuous cardiac output monitoring, no statistically significant differences were found in early haemodynamic indices although the stentless group required less inotropes and had a shorter ventilation time (16.1 +/- 4.2 hrs v 55.2 +/- 104.9 hrs) and intensive care stay (1.1 +/- 0.2 days v 4.6 +/- 8.3 days). Mean and peak aortic gradients one week postoperatively were lower in the stentless group (5.6 +/- 3 mmHg v 8.9 +/- 2.3 mmHg and 12.5 +/- 7.8 mmHg v 24.4 +/- 8.8 mmHg respectively). Magnetic resonance imaging at six months showed a 15% reduction in the end systolic muscle mass index in the stented group but a greater reduction of 29% in the stentless group. This study shows that despite requiring a more demanding technique of insertion, aortic valve replacement with the Toronto stentless porcine valve can produce satisfactory early clinical results.

摘要

相似文献

1
A three year experience with the toronto stentless porcine valve.
Ann Thorac Cardiovasc Surg. 1998 Jun;4(3):138-45.
2
Randomized controlled trial of stented and stentless aortic bioprotheses: hemodynamic performance at 3 years.
Semin Thorac Cardiovasc Surg. 1999 Oct;11(4 Suppl 1):93-7.
3
Are stentless valves hemodynamically superior to stented valves? Long-term follow-up of a randomized trial comparing Carpentier-Edwards pericardial valve with the Toronto Stentless Porcine Valve.无支架瓣膜在血流动力学方面优于支架瓣膜吗?一项比较 Carpentier-Edwards 心包瓣与 Toronto 无支架猪瓣的随机试验的长期随访。
J Thorac Cardiovasc Surg. 2010 Apr;139(4):848-59. doi: 10.1016/j.jtcvs.2009.04.067. Epub 2010 Jan 18.
4
Aortic valve replacement with stentless porcine aortic valves: a ten-year experience.无支架猪主动脉瓣置换术:十年经验
J Heart Valve Dis. 1998 May;7(3):250-4.
5
The Toronto root stentless valve in the subcoronary position is hemodynamically superior to the mosaic stented completely supra-annular bioprosthesis.置于冠状动脉下位置的多伦多无支架瓣膜在血流动力学上优于镶嵌式带支架完全瓣环上生物假体。
J Heart Valve Dis. 2005 Nov;14(6):814-21; discussion 821.
6
Aortic valve replacement with the Sorin Pericarbon Freedom stentless valve: five-year follow up.使用索林Pericarbon Freedom无支架瓣膜进行主动脉瓣置换术:五年随访
J Heart Valve Dis. 2007 Jan;16(1):42-8.
7
Stentless or stented aortic valve implants in elderly patients?老年患者使用无支架或带支架主动脉瓣植入物?
Eur J Cardiothorac Surg. 1999 Jan;15(1):31-6. doi: 10.1016/s1010-7940(98)00288-7.
8
Aortic valve replacement with the Cryolife-O'Brien stentless aortic bioprosthesis: five-year experience.使用Cryolife-O'Brien无支架主动脉生物瓣膜进行主动脉瓣置换术:五年经验
J Cardiovasc Surg (Torino). 2004 Dec;45(6):557-63.
9
Influence of stentless versus stented valves on ventricular remodeling assessed at 6 months by magnetic resonance imaging and long-term follow-up.无支架瓣膜与有支架瓣膜对心室重构的影响:通过磁共振成像在6个月时进行评估并长期随访
J Cardiol. 2017 Jan;69(1):264-271. doi: 10.1016/j.jjcc.2016.04.016. Epub 2016 Jun 16.
10
Aortic valve replacement with stentless and stented porcine valves: a case-match study.
J Thorac Cardiovasc Surg. 1998 Aug;116(2):236-41. doi: 10.1016/s0022-5223(98)70122-9.