Shirakashi M, Abe H, Sawaguchi S, Iwata K
Department of Ophthalmology, Niigata University School of Medicine, Japan.
Graefes Arch Clin Exp Ophthalmol. 1998 Jul;236(7):546-52. doi: 10.1007/s004170050119.
To investigate the correlation between the deterioration in optic disc cupping during the chronic elevation of intraocular pressure (IOP) and the reversal of cupping during a subsequent reduction in IOP in experimental glaucoma.
We examined changes in the vertical and horizontal cup to disc ratios, the rim area to disc area ratio, and the cup volume to disc area ratio in 11 monkey eyes with laser-induced glaucoma using computerized stereo-image analysis. Correlations between changes in disc parameters during a spontaneous IOP reduction and changes in disc parameters during a period of chronic IOP elevation from baseline before laser exposure (baseline) to before the IOP reduction (pre-IOP reduction) and during the period from baseline to after the reduction in IOP (post-IOP reduction) were determined by linear regression analysis.
All disc parameters improved significantly during IOP reduction and deteriorated significantly during the periods from baseline to the pre-IOP reduction and from baseline to the post-IOP reduction. The degree of reversal in disc parameters was correlated with the deterioration from baseline to the pre-IOP reduction and from baseline to the post-IOP reduction in the vertical cup to disc ratio (r = 0.68, P = 0.0218 and r = 0.97, P < 0.0001, respectively), the horizontal cup to disc ratio (r = 0.57, P = 0.0649 and r = 0.98, P < 0.0001, respectively), the rim area to disc area ratio (r = 0.68, P = 0.0227 and r = 0.98, P < 0.0001, respectively), and the cup volume to disc area ratio (r = 0.67, P = 0.0256 and r = 0.88, P = 0.0004, respectively).
The degree of deterioration in cupping from baseline before the induction of glaucoma may be an important determinant of the degree of cupping reversal during subsequent reductions in IOP in primate glaucoma.
研究实验性青光眼中眼压长期升高期间视盘杯状凹陷的恶化与随后眼压降低期间杯状凹陷逆转之间的相关性。
我们使用计算机立体图像分析检查了11只激光诱导性青光眼猴眼的垂直和水平杯盘比、盘缘面积与盘面积比以及杯体积与盘面积比的变化。通过线性回归分析确定了眼压自发降低期间视盘参数的变化与从激光暴露前的基线(基线)到眼压降低前(眼压降低前)的长期眼压升高期间以及从基线到眼压降低后(眼压降低后)视盘参数变化之间的相关性。
所有视盘参数在眼压降低期间均显著改善,在从基线到眼压降低前以及从基线到眼压降低后的期间均显著恶化。视盘参数的逆转程度与从基线到眼压降低前以及从基线到眼压降低后的垂直杯盘比(分别为r = 0.68,P = 0.0218和r = 0.97,P < 0.0001)、水平杯盘比(分别为r = 0.57,P = 0.0649和r = 0.98,P < 0.0001)、盘缘面积与盘面积比(分别为r = 0.68,P = 0.0227和r = 0.98,P < 0.0001)以及杯体积与盘面积比(分别为r = 0.67,P = 0.0256和r = 0.88,P = 0.0004)的恶化程度相关。
青光眼诱导前基线时杯状凹陷的恶化程度可能是灵长类青光眼随后眼压降低期间杯状凹陷逆转程度的重要决定因素。