Wahren E, Bengtsson C, Björkstén B, Mark A, Granström M
Department of Clinical Microbiology, Karolinska Hospital, Stockholm, Sweden.
Vaccine. 1998 May-Jun;16(9-10):873-6. doi: 10.1016/s0264-410x(97)00274-0.
A capture IgE assay in EIA with diphtheria toxin and tetanus toxoid as model systems was developed and evaluated in relation to RIA in a DT booster study. The EIA and the RIA gave very similar results, although the EIA determined IgE over a wider range of concentrations, without interference by other subclasses. The comparison to the capture EIA indicated that the RIA gave more reliable results when a toxin as antigen. Weak correlations between local side effects and IgE responses and differences between vaccine groups were noted by RIA but not by EIA, which correlated better with the clinical findings.
在一项白喉类毒素加强免疫研究中,开发并评估了以白喉毒素和破伤风类毒素作为模型系统的酶免疫分析(EIA)捕获IgE检测法,并与放射免疫分析(RIA)进行了比较。EIA和RIA得出了非常相似的结果,尽管EIA能在更宽的浓度范围内测定IgE,且不受其他亚类的干扰。与捕获EIA的比较表明,当以毒素作为抗原时,RIA给出的结果更可靠。RIA检测到局部副作用与IgE反应之间存在弱相关性以及疫苗组之间存在差异,但EIA未检测到,EIA与临床结果的相关性更好。