用于牛肉胴体上大肠杆菌O157:H7计数的Petrifilm HEC测试的重复性及其与疏水网格膜过滤法的一致性

Repeatability of the Petrifilm HEC test and agreement with a hydrophobic grid membrane filtration method for the enumeration of Escherichia coli O157:H7 on beef carcasses.

作者信息

Power C A, McEwen S A, Johnson R P, Shoukri M M, Rahn K, Griffiths M W, De Grandis S A

机构信息

Department of Population Medicine, Ontario Veterinary College, University of Guelph, Canada.

出版信息

J Food Prot. 1998 Apr;61(4):402-8. doi: 10.4315/0362-028x-61.4.402.

Abstract

The Petrifilm HEC test (3M Canada Inc., London, Ontario), a quantitative microbiological test for Escherichia coli O157:H7, was evaluated for its performance as a beef-carcass monitoring test. Test repeatability and agreement and agreement with an E. coli O157:H7 detection method using a hydrophobic grid membrane filter (HGMF) overlaid onto cefixime-tellurite-sorbitol MacConkey agar (CT-SMAC) followed by a latex agglutination test for the O157 antigen were determined by using pure cultures of E. coli O157:H7, beef samples experimentally contaminated with bovine feces containing E. coli O157:H7, and naturally contaminated beef carcasses of unknown E. coli O157:H7 status from a local abattoir. The Petrifilm HEC test showed excellent repeatability and excellent agreement with the HGMF-CT-SMAC method when test samples were obtained from pure cultures and experimentally contaminated meat. All 125 naturally contaminated beef carcasses surveyed were negative for E. coli O157:H7 with both microbial methods. The Petrifilm HEC test, however, demonstrated a significantly lower proportion of cross-reactive organisms (false-positive reactions) than the HGMF-CT-SMAC method. Given the performance of this test coupled with its ease of use and compact size, it shows considerable promise for carcass testing where abattoir laboratory facilities are limited and as a substitute for more complex laboratory testing methods used in established laboratories.

摘要

对用于检测大肠杆菌O157:H7的Petrifilm HEC检测法(加拿大3M公司,安大略省伦敦市)作为牛肉胴体监测检测方法的性能进行了评估。通过使用大肠杆菌O157:H7的纯培养物、经含大肠杆菌O157:H7的牛粪实验性污染的牛肉样本以及来自当地屠宰场的大肠杆菌O157:H7状态未知的天然污染牛肉胴体,确定了该检测法的重复性、与使用覆盖在头孢克肟-亚碲酸盐-山梨醇麦康凯琼脂(CT-SMAC)上的疏水网格膜过滤器(HGMF)然后进行O157抗原乳胶凝集试验的大肠杆菌O157:H7检测方法的一致性。当从纯培养物和经实验污染的肉中获取检测样本时,Petrifilm HEC检测法显示出优异的重复性以及与HGMF-CT-SMAC方法的良好一致性。两种微生物检测方法对所有125份检测的天然污染牛肉胴体的检测结果均显示大肠杆菌O157:H7呈阴性。然而,与HGMF-CT-SMAC方法相比,Petrifilm HEC检测法显示出交叉反应性微生物(假阳性反应)的比例显著更低。鉴于该检测法的性能及其易用性和小巧的尺寸,在屠宰场实验室设施有限的情况下,它在胴体检测方面显示出巨大潜力,并且可作为既定实验室中使用的更复杂实验室检测方法的替代方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验