To describe the short- and long-term outcomes of the removal of occluded stents.
With fluoroscopic guidance, 571 lacrimal polyurethane stents were placed in 502 patients with epiphora due to obstruction of the lacrimal system. Of the 571 stents, 142 were removed 2 weeks to 42 months (mean, 7 months) after placement because of recurrent epiphora, and the lacrimal system was irrigated with saline solution through the lacrimal point.
Stent removal was well tolerated. Mild epistaxis occurred in one patient and was controlled with a nasal pack. Recurrent epiphora was due to obstruction of the stent with mucoid material in 49 (35%) of 142 systems and granulation tissue in 93 (65%) systems. After stent removal, 73 (51%) of the 142 lacrimal systems showed improvement of epiphora, with a patent lacrimal system at 7-day follow-up dacryocystography. During the follow-up of 2 weeks to 49 months (mean, 22 months) after stent removal, patency was maintained in 24 (33%) of the 73 lacrimal systems.
Removal of an occluded lacrimal plastic stent was easy and safe. Recurrent epiphora after placement of lacrimal plastic stents can be treated with removal of the occluded stents an irrigation with saline solution through the lacrimal point, which resulted in a patent lacrimal system in 33% of cases in this study.
描述取出阻塞支架的短期和长期结果。
在荧光透视引导下,为502例因泪道系统阻塞而溢泪的患者置入571枚泪道聚氨酯支架。在这571枚支架中,142枚在置入后2周~42个月(平均7个月)因复发性溢泪而被取出,通过泪点用盐溶液冲洗泪道系统。
支架取出耐受性良好。1例患者出现轻度鼻出血,经鼻腔填塞后得到控制。142个泪道系统中,49个(35%)复发性溢泪是由于支架被黏液样物质阻塞,93个(65%)是由于肉芽组织阻塞。取出支架后,142个泪道系统中有73个(51%)溢泪情况改善,在7天随访泪囊造影时泪道系统通畅。在取出支架后2周~49个月(平均22个月)的随访中,73个泪道系统中有24个(33%)保持通畅。
取出阻塞的泪道塑料支架简便且安全。泪道塑料支架置入后复发性溢泪可通过取出阻塞支架并经泪点用盐溶液冲洗来治疗,在本研究中,33%的病例由此使泪道系统通畅。