• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Should unipolar leads be implanted in the atrium? A Holter electrocardiographic comparison of threshold adapted unipolar and high sensitive bipolar sensing.

作者信息

Wiegand U K, Schier H, Bode F, Brandes A, Potratz J

机构信息

Medical University of Luebeck, Department of Cardiology, Germany.

出版信息

Pacing Clin Electrophysiol. 1998 Aug;21(8):1601-8. doi: 10.1111/j.1540-8159.1998.tb00249.x.

DOI:10.1111/j.1540-8159.1998.tb00249.x
PMID:9725160
Abstract

The accuracy of atrial sensing plays a central role in dual chamber pacing. Recent Holter electrocardiographic studies showed a high incidence of atrial malsensing. We investigated the efficacy of bipolar atrial sensing at high sensitivity compared to threshold adapted unipolar sensing. One hundred consecutive patients with identical dual chamber pacemakers and bipolar atrial leads were investigated. Mean and individual range of 40 unipolar and bipolar telemetered atrial potentials were calculated; sensing threshold was determined by a semiautomatic sensing test. Oversensing was investigated with the help of a muscle provocation test. Twenty-four-hour Holter monitoring was performed at the highest bipolar sensitivity as well as at a unipolar sensitivity of half the measured sensing threshold. Mean atrial potential was significantly lower during bipolar mode compared to the unipolar sensing configuration, 3.66 +/- 1.75 versus 3.85 +/- 1.62 mV, P = 0.02. The bipolar atrial potentials showed a higher individual range than the unipolar signals, 2.44 +/- 2.62 versus 1.79 +/- 0.92 mV, P < 0.01. Sensing threshold did not differ significantly, 2.76 +/- 1.33 versus 2.67 +/- 1.29 mV. Mean oversensing threshold was 1.21 mV at unipolar configuration, whereas oversensing could not be provoked at a bipolar sensitivity of 0.5 mV. The incidence of atrial undersensing was significantly higher at threshold adapted unipolar sensing compared to bipolar sensing at highest atrial sensitivity, 35% versus 22%, P = 0.04. Oversensing did not occur at bipolar sensing, but was observed in 56% of patients at unipolar mode. Thirty-two percent of patients showed both atrial undersensing and oversensing at the unipolar sensing configuration. The muscle provocation test reached a sensitivity of 89% and a specificity of 95% in prediction of atrial oversensing during daily life. In conclusion, unipolar atrial potentials are more stable than bipolar ones. On the other hand, bipolar atrial sensing is less prone to the perception of myopotentials. Programming a high bipolar sensitivity significantly improves atrial sensing. Thus, bipolar leads should generally be implanted in the atrium.

摘要

相似文献

1
Should unipolar leads be implanted in the atrium? A Holter electrocardiographic comparison of threshold adapted unipolar and high sensitive bipolar sensing.
Pacing Clin Electrophysiol. 1998 Aug;21(8):1601-8. doi: 10.1111/j.1540-8159.1998.tb00249.x.
2
Efficacy and safety of bipolar sensing with high atrial sensitivity in dual chamber pacemakers.双腔起搏器中高心房感知度的双极感知的疗效与安全性
Pacing Clin Electrophysiol. 2000 Apr;23(4 Pt 1):427-33. doi: 10.1111/j.1540-8159.2000.tb00822.x.
3
Unipolar sensing in contemporary pacemakers: using myopotential testing to define optimal sensitivity settings.
J Interv Card Electrophysiol. 1998 Mar;2(1):33-40. doi: 10.1023/a:1009708606035.
4
Comparative evaluation of acute and long-term clinical performance of two single lead atrial synchronous ventricular (VDD) pacemakers: diagonally arranged bipolar versus closely spaced bipolar ring electrodes.两款单导联心房同步心室(VDD)起搏器急性和长期临床性能的比较评估:对角排列双极电极与紧密间隔双极环形电极。
Pacing Clin Electrophysiol. 1996 Nov;19(11 Pt 1):1574-81. doi: 10.1111/j.1540-8159.1996.tb03183.x.
5
Bipolar ventricular far-field signals in the atrium.心房中的双极心室远场信号。
Pacing Clin Electrophysiol. 1999 Nov;22(11):1604-13. doi: 10.1111/j.1540-8159.1999.tb00379.x.
6
Pacing and sensing disturbances in patients with DDD pacemakers in the early period after implantation.植入后早期 DDD 起搏器患者的起搏和感知障碍
Acta Cardiol. 2006 Jun;61(3):289-94. doi: 10.2143/AC.61.3.2014830.
7
Impact of programmed sensitivity safety factor on atrial sensing in children.程控灵敏度安全系数对儿童心房感知的影响。
Pacing Clin Electrophysiol. 1997 Sep;20(9 Pt 1):2163-70. doi: 10.1111/j.1540-8159.1997.tb04232.x.
8
The clinical relevance of electromyopotential oversensing in current unipolar devices.当前单极设备中肌电信号过感知的临床相关性。
Pacing Clin Electrophysiol. 1992 Nov;15(11 Pt 2):2023-7. doi: 10.1111/j.1540-8159.1992.tb03014.x.
9
VDD(R) pacing: short- and long-term stability of atrial sensing with a single lead system.VDD(R)起搏:单导联系统心房感知的短期和长期稳定性
Pacing Clin Electrophysiol. 1996 Apr;19(4 Pt 1):455-64. doi: 10.1111/j.1540-8159.1996.tb06516.x.
10
Spontaneous daily variability of atrial sensitivity. A study with an implanted DDD pacemaker.心房敏感性的自发性每日变化。一项使用植入式DDD起搏器的研究。
Int J Cardiol. 2001 Feb;77(2-3):287-91. doi: 10.1016/s0167-5273(00)00448-4.

引用本文的文献

1
[Guidelines for heart pacemaker therapy].[心脏起搏器治疗指南]
Z Kardiol. 2005 Oct;94(10):704-20. doi: 10.1007/s00392-005-0269-3.