Suppr超能文献

使用彩色和能量多普勒超声识别与甲状旁腺腺瘤相关的供血动脉。

Use of color and power Doppler sonography to identify feeding arteries associated with parathyroid adenomas.

作者信息

Lane M J, Desser T S, Weigel R J, Jeffrey R B

机构信息

Department of Radiology, Stanford University Hospital and School of Medicine, CA 94305, USA.

出版信息

AJR Am J Roentgenol. 1998 Sep;171(3):819-23. doi: 10.2214/ajr.171.3.9725323.

Abstract

OBJECTIVE

The objective of our study was to determine the value of using color and power Doppler sonography to reveal extrathyroidal feeding arteries in the detection of abnormal parathyroid glands.

SUBJECTS AND METHODS

Forty-four patients with primary hyperparathyroidism were imaged prospectively with high-resolution gray-scale, color flow, and power Doppler sonography. The presence of extrathyroidal arteries supplying the adenomas was noted. All patients underwent subsequent neck exploration. The locations of the abnormal glands were recorded.

RESULTS

At surgery, 51 abnormal parathyroid glands were removed in the 44 patients. Sonography correctly revealed an adenoma in 40 of the 44 patients. Likewise, sonography revealed 42 of the 51 adenomas. Nine false-negative and two false-positive interpretations of the sonograms were made. Thus, overall sensitivity was 83%, specificity was 98%, and accuracy was 94%. Three of the false-negative interpretations were ectopic glands within the superior mediastinum. Excluding these three glands from analysis, the sensitivity for detection of adenomas within the neck was 88%, specificity was 98%, and accuracy was 95%. An extrathyroidal artery leading to a parathyroid adenoma was seen in 35 of the 42 adenomas revealed by sonography. The presence of an extrathyroidal artery leading to an adenoma was found to aid in the detection of an otherwise inconspicuous parathyroid gland in five patients, which improved sensitivity from 73% to 83%.

CONCLUSION

Prominent vessels supplying parathyroid adenomas are frequently revealed by color flow and power Doppler sonography. These vessels can serve as "road maps" to abnormal parathyroid glands.

摘要

目的

本研究的目的是确定在检测异常甲状旁腺时,使用彩色和能量多普勒超声显示甲状腺外供血动脉的价值。

对象与方法

对44例原发性甲状旁腺功能亢进患者进行前瞻性高分辨率灰阶、彩色血流和能量多普勒超声检查。记录供应腺瘤的甲状腺外动脉的存在情况。所有患者随后均接受颈部探查。记录异常腺体的位置。

结果

手术中,44例患者共切除51个异常甲状旁腺。超声检查在44例患者中的40例中正确显示了腺瘤。同样,超声检查发现了51个腺瘤中的42个。超声检查有9例假阴性和2例假阳性解读。因此,总体敏感性为83%,特异性为98%,准确性为94%。3例假阴性解读是位于上纵隔内的异位腺体。将这3个腺体排除在分析之外,颈部腺瘤检测的敏感性为88%,特异性为98%,准确性为95%。在超声检查发现的42个腺瘤中的35个中可见一条通向甲状旁腺腺瘤的甲状腺外动脉。发现通向腺瘤的甲状腺外动脉的存在有助于在5例患者中检测到原本不明显的甲状旁腺,使敏感性从73%提高到83%。

结论

彩色血流和能量多普勒超声经常能显示供应甲状旁腺腺瘤的明显血管。这些血管可作为通向异常甲状旁腺的“路线图”。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验