[Concentration-dependent changes in the latency and amplitude of somatosensory-evoked potentials by desflurane, isoflurane and sevoflurane].

作者信息

Rehberg B, Rüschner R, Fischer M, Ebeling B J, Hoeft A

机构信息

Klinik und Poliklinik für Anästhesiologie, Universität Bonn.

出版信息

Anasthesiol Intensivmed Notfallmed Schmerzther. 1998 Jul;33(7):425-9. doi: 10.1055/s-2007-994279.

Abstract

PURPOSE

Comparison of the influence of desflurane, isoflurane, and sevoflurane on the parameters of cortical somatosensory evoked potentials (SEP).

METHODS

A total of 41 patients were randomly allocated to either the isoflurane, desflurane or sevoflurane group. Following induction with propofol and intubation, concentration of the volatile anaesthetic was kept constant at 1.3, 1.0, and 0.7 MAC for 15 minutes each in randomised sequences. No opioids or N2O were used. Cortical somatosensory evoked potentials were recorded following median nerve stimulation at the wrist with 1.5 times motor threshold current. SEP were evaluated for latencies of peak N20 and P25 as well as peak-to-peak amplitude N20P25. Measurements at the end of the 15 minute equilibration intervals were compared by analysis of variance for repeated measurements. Latencies and the logarithm of the amplitudes were assumed to be normally distributed.

RESULTS

SEP could be recorded in all patients and at all concentrations. Latency of cortical SEP increased with anaesthetic concentration in a linear manner. No differences in latency increase were found between the three anaesthetics (ANOVA). In contrast, the decrease in amplitude with increasing anaesthetic concentration was non-linear. It was large from control to 0.7 MAC, but small in the range between 0.7 and 1.3 MAC. Amplitude reduction was larger with isoflurane than with sevoflurane or desflurane.

CONCLUSION

  1. Sevoflurane and desflurane are better suited for anaesthetic management during intraoperative electrophysiological monitoring than isoflurane, because SEP amplitudes are better preserved. 2) SEP amplitude is less altered by changing anaesthetic concentrations in the concentration range from 0.7 to 1.3 MAC than SEP latency.
摘要

目的

比较地氟烷、异氟烷和七氟烷对皮质体感诱发电位(SEP)参数的影响。

方法

41例患者被随机分为异氟烷组、地氟烷组或七氟烷组。在丙泊酚诱导插管后,挥发性麻醉剂浓度以随机顺序分别在1.3、1.0和0.7 MAC下保持恒定15分钟。未使用阿片类药物或氧化亚氮。用1.5倍运动阈电流刺激腕部正中神经后记录皮质体感诱发电位。评估SEP的N20和P25峰潜伏期以及N20P25峰峰值幅度。通过重复测量方差分析比较15分钟平衡期结束时的测量值。潜伏期和幅度的对数假定呈正态分布。

结果

所有患者在所有浓度下均能记录到SEP。皮质SEP潜伏期随麻醉剂浓度呈线性增加。三种麻醉剂之间在潜伏期增加方面未发现差异(方差分析)。相反,随着麻醉剂浓度增加幅度下降呈非线性。从对照到0.7 MAC下降幅度大,但在0.7至1.3 MAC范围内下降幅度小。异氟烷导致的幅度降低大于七氟烷或地氟烷。

结论

1)七氟烷和地氟烷比异氟烷更适合术中电生理监测期间的麻醉管理,因为SEP幅度保存更好。2)在0.7至1.3 MAC浓度范围内,改变麻醉剂浓度时SEP幅度的改变小于SEP潜伏期。