Accuracy of reagent strips in detecting hypoglycemia in the emergency department.

作者信息

Scott P A, Wolf L R, Spadafora M P

机构信息

Section of Emergency Medicine, University of Michigan Medical Center, Ann Arbor 48109-0303, USA.

出版信息

Ann Emerg Med. 1998 Sep;32(3 Pt 1):305-9. doi: 10.1016/s0196-0644(98)70005-8.

DOI:10.1016/s0196-0644(98)70005-8
PMID:9737491
Abstract

STUDY OBJECTIVE

Although reagent strips are commonly used, their reliability to estimate blood glucose concentration and guide administration of dextrose solutions in the emergency department environment has not been proved. We determined the accuracy of visually interpreted reagent strips (Chemstrip bG, Boehringer Mannheim Corp, Indianapolis, IN) and their ability to identify hypoglycemic patients in the ED.

METHODS

We conducted a prospective, nonrandomized blinded clinical study of the visual estimation of blood glucose values by ED personnel using Chemstrip bG reagent strips during a 4-month period. Simultaneously obtained blood samples sent for laboratory glucose determination served as controls. The study was conducted at a large university hospital ED with an urban patient population. A convenience sample of 215 adult ED patients underwent serum glucose determination with data form completion. No study intervention was tested, although timing of administration of dextrose solutions, if given, was recorded.

RESULTS

Hypoglycemia was defined as a glucose concentration less than 60 mg/dL on standard laboratory analysis. Reagent strips identified 28 of 29 of these patients (sensitivity=97%), and 171 of 182 patients without hypoglycemia (specificity=94%, negative predictive value=99%) compared with control samples. The 1 false-negative reagent strip reading of 80 mg/dL was obtained from blood stored in a serum separator tube and had a laboratory glucose value of 39 mg/dL. Eighty-seven percent of the reagent strips were within +/-60 mg/dL of the control value for the laboratory glucose reference range less than 350 mg/dL.

CONCLUSION

Visually interpreted Chemstrip bG reagent strips provide an acceptable estimation of blood glucose concentration in the ED and are highly sensitive in detecting hypoglycemia.

摘要

相似文献

1
Accuracy of reagent strips in detecting hypoglycemia in the emergency department.
Ann Emerg Med. 1998 Sep;32(3 Pt 1):305-9. doi: 10.1016/s0196-0644(98)70005-8.
2
A clinical comparison of the performance of four blood glucose reagent strips.
Am J Emerg Med. 1990 Jan;8(1):11-5. doi: 10.1016/0735-6757(90)90286-9.
3
Comparison of Visidex and Chemstrip bG with Beckman Glucose Analyzer determination of blood glucose.
Diabetes Care. 1983 Nov-Dec;6(6):536-9. doi: 10.2337/diacare.6.6.536.
4
Determination of prehospital blood glucose: a prospective, controlled study.
J Emerg Med. 1992 Nov-Dec;10(6):679-82. doi: 10.1016/0736-4679(92)90524-w.
5
A prospective evaluation of glucose reagent teststrips in the prehospital setting.院前环境中葡萄糖试剂测试条的前瞻性评估。
Am J Emerg Med. 1991 Jul;9(4):304-8. doi: 10.1016/0735-6757(91)90046-m.
6
Detection of neonatal hypoglycemia--a comparison of three reagent strips.新生儿低血糖的检测——三种试纸条的比较
Nurse Pract. 1988 Oct;13(10):15-6, 18, 23-4.
7
Bedside blood glucose determinations in critical care medicine: a comparative analysis of two techniques.
Crit Care Med. 1982 Jul;10(7):463-5. doi: 10.1097/00003246-198207000-00012.
8
A comparison of chromogen test strip (Chemstrip bG) and serum glucose values in newborns.新生儿中色原试纸(Chemstrip bG)与血清葡萄糖值的比较。
Am J Dis Child. 1990 Feb;144(2):183-5. doi: 10.1001/archpedi.1990.02150260063029.
9
Assessment of a new blood glucose strip: comparison of Visidex, Visidex II, and Chemstrip bG with Glucose Analyzer determination of blood glucose.
Diabetes Care. 1985 Jan-Feb;8(1):77-82. doi: 10.2337/diacare.8.1.77.
10
Chemstrip glucose test strips: correlation with true glucose values less than 80 mg/dl.
Crit Care Med. 1983 Apr;11(4):293-5.

引用本文的文献

1
Low perfusion index affects the difference in glucose level between capillary and venous blood.低灌注指数会影响毛细血管和静脉血之间的血糖水平差异。
Ther Clin Risk Manag. 2014 Nov 20;10:985-91. doi: 10.2147/TCRM.S73359. eCollection 2014.