Wu J J, Chang T C, Chen H M
Department of Medical Technology, National Cheng Kung University Medical College, Tainan, Taiwan, Republic of China.
Zhonghua Min Guo Wei Sheng Wu Ji Mian Yi Xue Za Zhi. 1995 Aug;28(3):218-25.
Three rapid latex agglutination kits (Aureus Test, Pastorex Staph-Plus, and StaphAurex) and one hemagglutination test kit (SlidexStaph) were compared with the conventional coagulase test for the identification of Staphyloccus aureus. A total of 192 methicillin-resistant S. aureus (MRSA), 75 methicillin-susceptible S. aureus (MSSA) and 86 coagulase-negative staphylococci and Micrococcus spp. were tested. The sensitivities of Aureus Test, Pastorex Staph-Plus, StaphAurex and SlidexStaph were 98.6, 99.4, 90.8 and 97.3%, respectively. Capsular serotypes of 27 strains of MRSA were also determined, in which 15 (55.6%) were capsular serotype 5, 11 (40.7%) were capsular serotype 8, and 1 (3.7%) was nontypeable. All the commercial agglutination kits showed 100% specificity except StaphAurex which had a specificity of only 96.5%. False-positive reactions were found in the strains of S. hominis, S. warneri and unidentified coagulase-negative staphylococci. These results suggest that Aureus Test, Pastorex Staph-Plus, and SlidexStaph are better than StaphAurex for rapid identification of S. aureus.
将三种快速乳胶凝集试剂盒(金黄色葡萄球菌检测试剂盒、Pastorex Staph-Plus试剂盒和StaphAurex试剂盒)和一种血凝检测试剂盒(SlidexStaph试剂盒)与传统凝固酶试验进行比较,以鉴定金黄色葡萄球菌。共检测了192株耐甲氧西林金黄色葡萄球菌(MRSA)、75株甲氧西林敏感金黄色葡萄球菌(MSSA)以及86株凝固酶阴性葡萄球菌和微球菌属细菌。金黄色葡萄球菌检测试剂盒、Pastorex Staph-Plus试剂盒、StaphAurex试剂盒和SlidexStaph试剂盒的灵敏度分别为98.6%、99.4%、90.8%和97.3%。还测定了27株MRSA的荚膜血清型,其中15株(55.6%)为荚膜血清型5,11株(40.7%)为荚膜血清型8,1株(3.7%)无法分型。除StaphAurex试剂盒特异性仅为96.5%外,所有商用凝集试剂盒的特异性均为100%。在人葡萄球菌、华纳葡萄球菌和未鉴定的凝固酶阴性葡萄球菌菌株中发现了假阳性反应。这些结果表明,金黄色葡萄球菌检测试剂盒、Pastorex Staph-Plus试剂盒和SlidexStaph试剂盒在快速鉴定金黄色葡萄球菌方面优于StaphAurex试剂盒。