Abstract
  1. Both carotid and aortic arch baroreceptors have been shown to reset after as little as 20 min exposure to a different conditioning pressure; the mid-point of the stimulus-response curve is displaced towards the conditioning pressure. 2. Coronary baroreceptors operate over much lower pressures and induce slower reflex vasoconstriction than the other baroreceptors and this investigation was designed to determine whether their resetting characteristics are also different. 3. In chloralose anaesthetized dogs, a perfusion circuit allowed independent control of pressures distending carotid, aortic and coronary baroreceptors. Stimulus-response curves were obtained for carotid and coronary baroreceptors after maintaining the distending pressure at 60 or 180 mmHg for 20 min. 4. Neither the magnitude of the responses nor the baroreceptor pressure corresponding to 50 % of the response (BP50) of the coronary curves was changed by the conditioning regime. In contrast, conditioning carotid baroreceptors with the same regime produced significant shifts in the BP50 towards the conditioning pressure. 5. No changes were obtained after conditioning the coronary baroreceptors at 60 or 120 mmHg for 40 min. 6. These results confirm early resetting of carotid baroreceptors but show that coronary baroreceptors do not reset over a period of at least 40 min.
摘要
  1. 研究表明,仅暴露于不同的调节压力20分钟后,颈动脉和主动脉弓压力感受器就会发生重置;刺激-反应曲线的中点会向调节压力方向移动。2. 冠状动脉压力感受器在低得多的压力下发挥作用,与其他压力感受器相比,其诱导的反射性血管收缩较慢,本研究旨在确定它们的重置特性是否也不同。3. 在氯醛糖麻醉的犬中,一个灌注回路可独立控制扩张颈动脉、主动脉和冠状动脉压力感受器的压力。在将扩张压力维持在60或180 mmHg 20分钟后,获得了颈动脉和冠状动脉压力感受器的刺激-反应曲线。4. 调节方案既未改变冠状动脉曲线反应的幅度,也未改变对应于反应50%的压力感受器压力(BP50)。相比之下,用相同方案调节颈动脉压力感受器会使BP50向调节压力方向发生显著偏移。5. 在60或120 mmHg下对冠状动脉压力感受器进行40分钟的调节后,未出现变化。6. 这些结果证实了颈动脉压力感受器的早期重置,但表明冠状动脉压力感受器在至少40分钟的时间段内不会重置。

相似文献

本文引用的文献

1
PRESSOREFLEX ARISING FROM THE LEFT CORONARY ARTERY.
Jpn Circ J. 1963 Aug;27:575-84. doi: 10.1253/jcj.27.575.
7
Pharmacology and molecular biology of adrenergic receptors.
Baillieres Clin Endocrinol Metab. 1993 Apr;7(2):279-306. doi: 10.1016/s0950-351x(05)80178-8.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验