• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Time domain analysis of embolic signals can be used in place of high-resolution Wigner analysis when classifying gaseous and particulate emboli.

作者信息

Smith J L, Evans D H, Bell P R, Naylor A R

机构信息

Department of Surgery, Faculty of Medicine, University of Leicester, UK.

出版信息

Ultrasound Med Biol. 1998 Sep;24(7):989-93. doi: 10.1016/s0301-5629(98)00107-0.

DOI:10.1016/s0301-5629(98)00107-0
PMID:9809633
Abstract

The sample-volume length (SVL) of an embolic signal has previously been used to differentiate between gaseous and particulate emboli and has been calculated using high-resolution Wigner analysis. Although successful, this method of analysis is not widely available to other groups using transcranial Doppler ultrasound (TCD) to classify emboli. The SVL of embolic signals can also be calculated using time domain analysis, which is a far simpler method and potentially available to all TCD users. The aim of this study was to compare the SVL of embolic signals calculated using Wigner analysis and time domain analysis to assess whether or not time domain analysis can replace Wigner analysis to classify emboli. In total, 215 particulate and 100 gaseous emboli were recorded onto digital audiotape and analysed off-line. Two SVLs for each embolic signal were calculated by measuring embolic duration and velocity in the time domain and with Wigner analysis. Receiver operator characteristic (ROC) curves were plotted to assess the optimum SVL threshold for each method, and levels of sensitivity and specificity were defined. The optimum SVL threshold using Wigner analysis was 1.28 cm, yielding 93% sensitivity and 97% specificity. Using time domain analysis, the optimum threshold was 1.12 cm, yielding 90% sensitivity and 96% specificity. The methods were compared statistically (chi2) using their optimum thresholds, and were found not to be statistically different for classifying particles p=0.283) or gaseous emboli (p=0.700). This study has shown that the SVL of embolic signals, used to differentiate particulate from gaseous emboli, can be calculated more simply in the time domain, which yields as accurate results as calculating the SVL using Wigner analysis.

摘要

相似文献

1
Time domain analysis of embolic signals can be used in place of high-resolution Wigner analysis when classifying gaseous and particulate emboli.
Ultrasound Med Biol. 1998 Sep;24(7):989-93. doi: 10.1016/s0301-5629(98)00107-0.
2
A comparison of four methods for distinguishing Doppler signals from gaseous and particulate emboli.
Stroke. 1998 Jun;29(6):1133-8. doi: 10.1161/01.str.29.6.1133.
3
Interpretation of embolic phenomena during carotid endarterectomy.颈动脉内膜切除术期间栓塞现象的解读
Stroke. 1995 Dec;26(12):2281-4. doi: 10.1161/01.str.26.12.2281.
4
A method to distinguish between gaseous and solid cerebral emboli in patients with prosthetic heart valves.一种区分人工心脏瓣膜患者气态和固态脑栓塞的方法。
Eur J Cardiothorac Surg. 2009 Jan;35(1):89-95. doi: 10.1016/j.ejcts.2008.09.020. Epub 2008 Oct 25.
5
[Circulating cerebral microembolisms. Detection with transcranial Doppler ultrasound].[循环性脑微栓子。经颅多普勒超声检测]
Anasthesiol Intensivmed Notfallmed Schmerzther. 1996 Apr;31(3):127-31. doi: 10.1055/s-2007-995888.
6
Analysis of the frequency modulation present in Doppler ultrasound signals may allow differentiation between particulate and gaseous cerebral emboli.对多普勒超声信号中存在的频率调制进行分析,可能有助于区分颗粒性和气体性脑栓塞。
Ultrasound Med Biol. 1997;23(5):727-34. doi: 10.1016/s0301-5629(97)00003-3.
7
Can transcranial Doppler discriminate between solid and gaseous microemboli? Assessment of a dual-frequency transducer system.经颅多普勒能否区分固体和气体微栓子?双频换能器系统的评估。
Stroke. 2005 Aug;36(8):1731-4. doi: 10.1161/01.STR.0000173399.20127.b3. Epub 2005 Jul 14.
8
Distinguishing air from solid emboli using ultrasound: in-vitro study of the effect of Doppler carrier frequency.利用超声鉴别空气与固体栓子:多普勒载波频率效应的体外研究
J Neuroimaging. 2007 Jul;17(3):211-8. doi: 10.1111/j.1552-6569.2007.00107.x.
9
Differentiation between gaseous and formed embolic materials in vivo. Application in prosthetic heart valve patients.
Stroke. 1994 Aug;25(8):1559-63. doi: 10.1161/01.str.25.8.1559.
10
Differentiation between different pathological cerebral embolic materials using transcranial Doppler in an in vitro model.在体外模型中使用经颅多普勒区分不同病理性脑栓塞物质
Stroke. 1993 Jan;24(1):1-5. doi: 10.1161/01.str.24.1.1.