IJzerman M J, Baardman G, Hermens H J, Veltink P H, Boom H B, Zilvold G
Roessingh Research and Development b.v., Enschede, The Netherlands.
Arch Phys Med Rehabil. 1998 Nov;79(11):1408-14. doi: 10.1016/s0003-9993(98)90236-2.
To determine speed dependence of crutch force and oxygen uptake, and to discuss the implications of differences in self-selected walking speed between orthoses in a comparative trial.
Cross-sectional comparison.
Treadmill experiments and gait laboratory experiments were performed at five and three different imposed walking speeds, respectively.
Five paraplegic subjects with lesions between T9 and T12 were included. All subjects had experience with ambulation using the advanced reciprocating gait orthosis (ARGO) as well as walking on a treadmill.
Crutch force time integral (CFTI), crutch peak force on stance and swing side (CPFstance and CPFswing), oxygen uptake (VO2), oxygen cost (EO2).
VO2, EO2, and CFTI were strongly dependent on walking speed. CPFstance and CPFswing were less dependent. However, depending on the clinically relevant difference that should be detected in a comparative trial, the peak forces can still be confounded by walking speed.
CFTI, CPFswing, VO2, and EO2 should be adjusted for walking speed if differences in walking speed between orthoses are found, but this correction is relevant only if there is no effect modification. Such modification (different slopes between orthoses) cannot be excluded for the studied outcome measures. In addition, because determination of effect modification is difficult in small studies, standardization of walking speed, by means of a three-point design, is recommended.
确定拐杖力和摄氧量与速度的相关性,并在一项对比试验中探讨不同矫形器自定步行速度差异的影响。
横断面比较。
分别在5种和3种不同的设定步行速度下进行跑步机实验和步态实验室实验。
纳入5名胸9至胸12节段损伤的截瘫患者。所有受试者均有使用先进往复式步态矫形器(ARGO)行走以及在跑步机上行走的经验。
拐杖力时间积分(CFTI)、站立侧和摆动侧的拐杖峰值力(CPFstance和CPFswing)、摄氧量(VO2)、氧耗(EO2)。
VO2、EO2和CFTI强烈依赖于步行速度。CPFstance和CPFswing的依赖性较小。然而,根据对比试验中应检测到的临床相关差异,峰值力仍可能受步行速度的干扰。
如果发现矫形器之间的步行速度存在差异,CFTI、CPFswing、VO2和EO2应针对步行速度进行调整,但只有在不存在效应修饰的情况下,这种校正才有意义。对于所研究的观察指标,不能排除这种修饰(矫形器之间的斜率不同)。此外,由于在小型研究中难以确定效应修饰,建议通过三点设计对步行速度进行标准化。