Do quantitative ultrasound measurements reflect structure independently of density in human vertebral cancellous bone?

作者信息

Nicholson P H, Müller R, Lowet G, Cheng X G, Hildebrand T, Rüegsegger P, van der Perre G, Dequeker J, Boonen S

机构信息

Division of Biomechanics and Engineering Design, Katholieke Universiteit Leuven, Belgium.

出版信息

Bone. 1998 Nov;23(5):425-31. doi: 10.1016/s8756-3282(98)00128-8.

Abstract

Ultrasonic measurements were made in three orthogonal directions on 70 vertebral bone cubes. Apparent density (rho) was determined, and microcomputed tomography was used to derive a range of microstructural parameters. Qualitatively different ultrasonic behavior was observed in the craniocaudal (CC) axis, in which two distinct waves propagated. In this direction, only attenuation correlated strongly with rho (r2 = 80%), whereas, in the anteroposterior (AP) and mediolateral (ML) axes, there were significant correlations between all ultrasonic parameters and rho (r2 = 57%-79%). Microstructural parameters were, in general, correlated with ultrasonic properties, but when adjusted for rho, few significant relationships remained and the additional variance explained by individual microstructural parameters was relatively small (< 25% for CC axis, < 3% for AP, 0% for ML). In stepwise regression analysis including rho and all of the microstructural parameters, rho remained the primary determinant of ultrasonic properties in the transverse axes: Combinations of structural parameters explained, at most, an additional of 6% of the variability in ultrasonic properties in the AP axis, but failed to contribute significantly in the ML axis. In the CC axis, structural parameters played a greater role, but the pattern of associations was complex and the predictive power of the models was generally much less than that for the transverse axes. These data indicate that the ability of ultrasound to reflect aspects of trabecular structure is strongly dependent on the direction in which ultrasonic measurements are made, and provide only qualified support for the hypothesis that ultrasound reflects cancellous bone structure independently of bone density.

摘要

在70个椎体骨块的三个正交方向上进行了超声测量。测定了表观密度(rho),并使用微型计算机断层扫描得出一系列微观结构参数。在颅尾(CC)轴上观察到了性质不同的超声行为,在该轴上有两种不同的波传播。在这个方向上,只有衰减与rho密切相关(r2 = 80%),而在前后(AP)轴和中外侧(ML)轴上,所有超声参数与rho之间都存在显著相关性(r2 = 57%-79%)。微观结构参数一般与超声特性相关,但在对rho进行校正后,几乎没有显著关系留存,并且各个微观结构参数所解释的额外方差相对较小(CC轴<25%,AP轴<3%,ML轴为0%)。在包括rho和所有微观结构参数的逐步回归分析中,rho仍然是横向轴超声特性的主要决定因素:结构参数的组合最多只能解释AP轴超声特性变异性的额外6%,但在ML轴上没有显著贡献。在CC轴上,结构参数发挥了更大的作用,但关联模式复杂,模型的预测能力通常远低于横向轴。这些数据表明,超声反映小梁结构特征的能力强烈依赖于超声测量的方向,并且仅为超声独立于骨密度反映松质骨结构这一假设提供了有限的支持。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验