Comparison of power Doppler and B-scan sonography for renal imaging using a sonographic contrast agent.

作者信息

Sehgal C M, Arger P H, Pugh C R, Kirchofer J I, Kotlar E Y, Bovee K C

机构信息

Department of Radiology, University of Pennsylvania, Philadelphia, USA.

出版信息

J Ultrasound Med. 1998 Dec;17(12):751-6; quiz 757-8. doi: 10.7863/jum.1998.17.12.751.

Abstract

The goal of this study was to evaluate the relative performance of power Doppler and B-scan imaging modes in detecting vascular perfusion changes resulting from injection of a contrast agent. To allow this comparison the imaging plane and the contrast agent injection must be the same for both modes. We achieved this by using a rigid transducer holder and simultaneously recording power Doppler and B-scan images on separate videotapes. The kidneys of five adult beagles were scanned to allow a comparison of how power Doppler and B-scan imaging methods monitor changes during the injection of 0.1 ml/kg of a contrast agent, EchoGen emulsion (Sonus Pharmaceuticals, Bothell, WA). The changes in the images were assessed qualitatively by three radiologists and quantitatively using a custom-designed image analysis software. All of the radiologists agreed that no visually detectable changes occurred in B-scan images but that significant changes could be observed in power Doppler images. Image analysis also indicated a difference between power Doppler and B-scan images. The change in mean color level of power Doppler images could be displayed as an indicator dilution curve with a peak enhancement of 46 +/- 16 above the preinjection value. The time at which mean color level peaked was 18 +/- 13 s. The mean color level returned to half of the peak value by 69 +/- 42 s and returned to the preinjection baseline value by 148 +/- 73 s. Conversely, B-scan images showed statistically insignificant changes, and time measurements could not be made. By all measures used to evaluate images, power Doppler imaging had a greater sensitivity in detecting changes resulting from contrast agent injection than B-scan imaging. This finding indicates that power Doppler imaging of contrast agent injections can be used to map regional differences in flow as well as quantitative measurements of a contrast agent's transit time and has the potential to assess kidney abnormalities associated with renal blood flow.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验