Endothelialization of filtering bleb in iris nevus syndrome.

作者信息

Yanoff M, Scheie H G, Allman M I

出版信息

Arch Ophthalmol. 1976 Nov;94(11):1933-6. doi: 10.1001/archopht.1976.03910040639012.

Abstract

Late failure of a filtering cicatrix occurred in a patient who had had surgery to control the glaucoma associated with the iris nevus syndrome (Cogan-Reese). The internal surface of the filtration site, as well as the anterior chamber angle, proved to be lined by corneal endothelium that had laid down a new, thick basement membrane (Descemet). The new endothelium-basement membrane probably obstructed the flow of aqueous into the bleb. Endothelialization of a filtering bleb is not unique to the iris nevus syndrome; other causes are discussed.