Suppr超能文献

[震颤的直接定量测量:锂治疗患者中新测量程序的初步结果]

[Direct quantitative measurement of tremor: first results of a new mesuring procedure in patients under lithium therapy].

作者信息

Engel R R, Fischer J, Greil W

出版信息

Arzneimittelforschung. 1976;26(6):1126-8.

PMID:989396
Abstract

The use of a new piezoresistive minature accelerometer as part of an electronic measurement system for the direct quantification of human finger tremor in physical units is described. The system was designed to yield digital values for the mean tremor amplitude in a given period of time. Reliability coefficients were computed for a smaple of 34 patients under lithium therapy. Coefficients ranged between 0.75 and 0.94 for test-retest intervals between 30 min and several days. Some of the usual indirect methods for the assessment of tremor showed very low correlations to the true tremor amplitude and seemed to be only of limited usefulness. It was further demonstrated that situational factors play a dominant role independently of the particular method of measurement.

摘要

本文描述了一种新型压阻式微型加速度计作为电子测量系统的一部分,用于以物理单位直接量化人体手指震颤。该系统旨在给出给定时间段内平均震颤幅度的数字值。计算了34例接受锂治疗患者样本的可靠性系数。重测间隔在30分钟至数天之间时,系数范围为0.75至0.94。一些常用的震颤评估间接方法与真实震颤幅度的相关性非常低,似乎仅具有有限的用途。进一步证明,情境因素独立于特定测量方法起主导作用。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验