Suppr超能文献

离体犬脑大脑氧摄取与脑电图频率的关系。

Relationship of cerebral oxygen uptake to EEG frequency in isolated canine brain.

作者信息

Fitzpatrick J H, Gilboe D D, Drewes L R, Betz A L

出版信息

Am J Physiol. 1976 Dec;231(6):1840-6. doi: 10.1152/ajplegacy.1976.231.6.1840.

Abstract

Cerebral oxygen uptake was correlated with electroencephalographic (EEG) frequency and amplitude in 87 isolated canine brains. Group I (71 brains) was perfused with diluted blood and Group II (16 brains) was perfused with whole blood equilibrated with oxygen at various partial pressures. The EEG's were classified as follows: A, highest frequency greater than or equal to 17 Hz, alpha (8-13 Hz) amplitude less than 50 muv, delta (less than or equal to 3.5 Hz), amplitude less than 100 muv; B, highest frequency greater than or equal to 17 Hz, alpha amplitude greater to or equal to 50 muv, and/or delta amplitude greater than or equal to 100 muv. C, highest frequency 8-16 Hz, alpha amplitude greater than or equal to 25 muv, and delta amplitude greater than 100 muv, D, highest frequency 0.5-16 Hz, alpha, if present, amplitude less than 25 muv, and/or delta amplitude less than 100 muv, and E, highest frequency 0-16 Hz, alpha, if present, amplitude less than 10 muv, and/or delta amplitude less than 15 muv. The Group I oxygen uptakes in ml/100 g of brain per min+/-SE for the five EEG classifications were A, 4.39+/-0.06, B, 4.13+/-0.08, C, 3.76+/-0.09, D, 3.40+/-0.12, and E, 2.55+/-0.06, whereas the corresponding Group II values were A, 4.64+/-0.22, B, 4.28+/-0.15, C, 3.82+/-0.24, D, 3.39+/-0.40, and E, 1.38+/-0.42. As the EEG deteriorates, cerebral oxygen uptake tends to decrease in a significant and parallel manner in both the diluted and whole blood groups.

摘要

在87个离体犬脑标本中,对脑氧摄取量与脑电图(EEG)的频率和波幅进行了相关性研究。第一组(71个脑标本)用稀释血液灌注,第二组(16个脑标本)用在不同分压下与氧平衡的全血灌注。EEG分类如下:A类,最高频率大于或等于17Hz,α波(8 - 13Hz)波幅小于50μV,δ波(小于或等于3.5Hz)波幅小于100μV;B类,最高频率大于或等于17Hz,α波波幅大于或等于50μV,和/或δ波波幅大于或等于100μV;C类,最高频率8 - 16Hz,α波波幅大于或等于25μV,δ波波幅大于100μV;D类,最高频率0.5 - 16Hz,α波(若存在)波幅小于25μV,和/或δ波波幅小于100μV;E类,最高频率0 - 16Hz,α波(若存在)波幅小于10μV,和/或δ波波幅小于15μV。第一组中,五类EEG分类对应的脑氧摄取量(以每100g脑每分钟毫升数±标准误表示)分别为:A类,4.39±0.06;B类,4.13±0.(此处原文疑似有误,推测应为4.13±0.08);C类,3.76±0.09;D类,3.40±0.12;E类,2.55±0.06。而第二组对应的数值分别为:A类,4.64±0.22;B类,4.28±0.15;C类,3.82±0.24;D类,3.39±0.40;E类,1.38±0.42。随着EEG恶化,在稀释血液组和全血组中,脑氧摄取量均倾向于以显著且平行的方式下降。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验