Thaler A, Heilig P, Gordesch J
Bibl Ophthalmol. 1976(85):110-4.
In the clinical standard EOG procedure the light rise potential is influenced by the preceding dark troughs oscillation. This is apparent in the different configuration of the light rise potential when following a dark trough instead of a steady state. Uninfluenced responses can be obtained only under steady-state conditions. Recording of the light peak potential in this manner may be used on a trial basis for clinical routine examination. Experimental and more detailed clinical studies require separate recording of light peak and dark trough potential, each preceded by a steady state. The evaluation of these responses, expressing them in percent of the steady state, should reveal more information than can be expected from the standard light peak to dark trough ratio.
在临床标准眼电图(EOG)检查过程中,光峰电位受先前暗谷振荡的影响。当跟随暗谷而非稳态时,光峰电位的不同形态就体现了这一点。只有在稳态条件下才能获得不受影响的反应。以这种方式记录光峰电位可在临床常规检查中进行试验性应用。实验性和更详细的临床研究需要分别记录光峰电位和暗谷电位,且每次记录前都要有一个稳态。对这些反应进行评估,以稳态的百分比来表示,应该能揭示比标准光峰与暗谷比值更多的信息。